English
Related papers

Related papers: Test beam studies for a highly granular GRPC Semi-…

200 papers

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

A front-end readout system with a large dynamic range is required for the high-granularity crystal electromagnetic calorimeter (ECAL) at future Higgs factories. A new commercially available ASIC, MPT2321, which offers a significantly large…

Instrumentation and Detectors · Physics 2025-05-23 Baohua Qi , Yong Liu , Huangchao Shi , Danqi Wang , Zhiyu Zhao , Hongbo Zhu

A Resistive Plate Chamber using Diamond-Like Carbon electrodes (DLC-RPC) has been developed as a background tagging detector in the MEG$~$II experiment. The DLC-RPC is planned to be installed in a high-intensity and low-momentum muon beam.…

Instrumentation and Detectors · Physics 2025-06-13 Masato Takahashi , Sei Ban , Weiyuan Li , Atsuhiko Ochi , Wataru Ootani , Atsushi Oya , Hiromu Suzuki , Kensuke Yamamoto

Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density…

To achieve the physics goal of precisely measure the Higgs, Z, W bosons and the top quark, future electron-positron colliders require that their detector system has excellent jet energy resolution. One feasible technical option is the high…

The Digital Hadron Calorimeter (DHCAL) is a large prototype of an imaging calorimeter using Resistive Plate Chambers (RPCs) as active media. The readout is segmented into 1\times1 cm2 pads, each with a single bit resolution, hence the…

Instrumentation and Detectors · Physics 2012-04-17 Jose Repond

The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…

The CALICE collaboration conducts calorimeter R&D for highly granular calorimeters, mainly for their application in detectors for a future lepton collider at the TeV scale. The activities ranges from generic R&D with small devices up to…

Instrumentation and Detectors · Physics 2013-03-12 The CALICE Collaboration

This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us…

Instrumentation and Detectors · Physics 2021-02-03 Jaydeep Datta , Sridhar Tripathy , Nayana Majumdar , Supratik Mukhopadhyay

The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technologies which can achieve fine granularity required for the particle flow algorithm. Second prototype of the ScECAL has been built and tested with…

Instrumentation and Detectors · Physics 2019-08-13 Satoru Uozumi

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL of the International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future…

Instrumentation and Detectors · Physics 2020-06-17 D. Breton , A. Irles , J. Jeglot , J. Maalmi , R. Pöschl , D. Zerwas

The ATLAS Muon Spectrometer is undergoing a major upgrade for the High-Luminosity LHC (HL-LHC), including the addition of three new thin-gap Resistive Plate Chamber (RPC) layers in the inner barrel region. These RPCs have 1 mm gas gaps…

Instrumentation and Detectors · Physics 2025-01-10 F. Fallavollita , O. Kortner , H. Kroha , P. Maly , G. Proto , D. Soyk , E. Voevodina , J. Zimmermann

In this study, we propose a novel fully active total absorption calorimeter with enhanced read out capabilities through fine splitting. The proposed calorimeter employs a sandwich structure composed of scintillator glasses and lead glasses,…

Instrumentation and Detectors · Physics 2023-07-04 T. Takeshita , R. Terada

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

Instrumentation and Detectors · Physics 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

CEPC (Circular Electron and Positron Collider) is a large experiment facility proposed by Chinese particle physics community. One of its running option is being the Higgs factory. Calorimeter is the main part of this experiment to measure…

Instrumentation and Detectors · Physics 2019-09-04 Yu Wang , Shubin Liu , Changqing Feng , Zhongtao Shen , Junbin Zhang , Daojin Hong , Jianbei Liu , Yi Zhou

An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common…

High Energy Physics - Experiment · Physics 2023-04-28 Vincent Boudry

The SDHCAL prototype that was completed in 2012 was exposed to beams of pions, electrons of different energies at the SPS of CERN for a total time period of 5 weeks. The data are being analyzed within the CALICE Collaboration. However…

Instrumentation and Detectors · Physics 2014-06-30 Alexey Petrukhin

The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for…

Instrumentation and Detectors · Physics 2018-07-01 Florian Pitters

The evolution of particle detectors dates back to the discovery of X-rays and radioactivity in 1890s. In detector history, the Resistive Plate Chambers (RPCs) are introduced in early 1980s. An RPC is a gaseous detector made up of two…

Instrumentation and Detectors · Physics 2018-11-20 Manisha , V. Bhatnagar , J. S. Shahi , S. Verma , B. P. Mohanty , A. Kumar

The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for…

Instrumentation and Detectors · Physics 2018-02-18 Arabella Martelli
‹ Prev 1 4 5 6 7 8 10 Next ›