English

AHCAL Energy Resolution

Instrumentation and Detectors 2010-06-21 v1

Abstract

The CALICE collaboration has constructed highly granular hadronic and electromagnetic calorimeter prototypes to evaluate technologies for the use in detector systems at a future Linear Collider. The hadron calorimeter uses 7608 small scintillator cells individually read out with silicon photomultipliers. This high granularity opens up the possibility for precise three dimensional shower reconstruction and for software compensation techniques to improve the energy resolution of the detector. We discuss the calibration procedure for the analog hadronic calorimeter and present two software compensation methods based on reconstructed clusters, which were developed with simulations and are applied to hadronic test beam data.

Keywords

Cite

@article{arxiv.1006.3712,
  title  = {AHCAL Energy Resolution},
  author = {Katja Seidel},
  journal= {arXiv preprint arXiv:1006.3712},
  year   = {2010}
}

Comments

5 pages, 8 figures, Linear Collider Workshop 2010 Conference Proceedings