Scintillator-Based Electromagnetic Calorimeter Prototype and Beam Test Results at FNAL

Instrumentation and Detectors 2010-07-16 v1 High Energy Physics - Experiment

Abstract

A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with hadronic calorimeter and Tail catcher. One of the main objectives of the CALICE program is to establish the technology of Scintillator-based electromagnetic calorimeter and validate the prformance of the calorimeter. From preliminary results of the first approach of analysis with electron beam, we obtain the ScECAL energy resolution {\sigma}stochastic = 15.15+/-0.03% and {\sigma}constant = 1.44+/-0.02% . The deviation from the linear response is calculated to be less than 6%.

Keywords

Cite

@article{arxiv.1007.2553,
  title  = {Scintillator-Based Electromagnetic Calorimeter Prototype and Beam Test Results at FNAL},
  author = {Adil Khan},
  journal= {arXiv preprint arXiv:1007.2553},
  year   = {2010}
}

Comments

4 pages, 9 figure, International Linear Collider Workshop 2010, LCWS10 and ILC10 March 26-30, 2010 China