Related papers: Integrated Circuit Readout for the Silicon Sensor …
Collider detectors have taken advantage of the resolution and accuracy of silicon detectors for at least four decades. Future colliders will need large areas of silicon sensors for low mass trackers and sampling calorimetry. Monolithic…
Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector…
A prototype detector for Compton camera imaging is under development. A monolithic array of 19 channel Silicon drift detector with on-chip electronics is going to be used as a scatter detector for the prototype system. Custom designed…
This paper describes a highly integrated, low power chip solution for ECG signal processing in wearable devices. The chip contains an instrumentation amplifier with programmable gain, a band-pass filter, a 12-bit SAR ADC, a novel QRS…
On-chip thermometry at deep-cryogenic temperatures is vital in quantum computing applications to accurately quantify the effect of increased temperature on qubit performance. In this work, we present a sub-1 K temperature sensor in CMOS…
The readout chip for the CMS pixel detector has to deal with an enormous data rate. On-chip zero suppression is inevitable and hit data must be buffered locally during the latency of the first level trigger. Dead-time must be kept at a…
The RD53 collaboration is currently designing a large scale prototype pixel readout chip in 65 nm CMOS technology for the phase 2 upgrades at the HL-LHC. The RD53A chip will be available by the end of the year 2017 and will be extensively…
The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an…
In this paper we present a simple and efficient built-in temperature sensor for thermal monitoring of standard-cell based VLSI circuits. The proposed smart temperature sensor uses a ring-oscillator composed of complex gates instead of…
We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS…
In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…
The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the…
When testing and calibrating particle detectors in a test beam, accurate tracking information independent of the detector being tested is extremely useful during the offline analysis of the data. A general-purpose Silicon Beam Tracker (SBT)…
We demonstrate the design of an integrated conditional quantum teleportation circuit and a readout circuit using a two-dimensional photonic crystal single chip. Fabrication and testing of the proposed quantum circuit can be accomplished…
High channel density and space restrictions required that the front end electronics integrated into the active elements of calorimeter. For that purpose novel readout chain base on Application-Specific Integrated Circuit (ASIC) designed for…
This paper presents the design and post-layout characteristics of a differential capacitance based inertial accelerometer This includes a MEMS based mechanical sensing element and a CMOS charge amplifier, which is the first stage of a…
We present an approach to construct position-sensitive silicon detectors with an integrated cooling circuit. Tests on samples demonstrate that a very modest liquid flow very effectively cool the devices up to a power dissipation of over…
CLIC is a proposed linear $e^+e^-$ collider with center-of-mass energies of up to 3 TeV. Its main objectives are precise top quark, Higgs boson and Beyond Standard Model physics. In addition to spatial resolutions of a few micrometers and a…
High-granularity calorimeters utilizing silicon pad sensors as main active material are being designed for the CMS endcap calorimeter upgrade and have been proposed for the electromagnetic calorimeters at CLIC, ILC and FCC-ee. The silicon…
This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the induction gap in GEM based detectors. The measurement will…