Related papers: A Microcantilever-based Gas Flow Sensor for Flow R…
In this paper an experimental validation of numerical approaches aimed to predict the coupled behaviour of microbeams for out-of-plane bending tests is performed. This work completes a previous investigation concerning in plane microbeams…
The present work investigates the fluid-structure interaction (FSI) of a flexible cylindrical cantilever in a tandem configuration. A fully coupled fluid-structure solver based on the three-dimensional incompressible Navier-Stokes equations…
Frequency dependent dynamic behavior in Piezoresponse Force Microscopy (PFM) implemented on a beam-deflection atomic force microscope (AFM) is analyzed using a combination of modeling and experimental measurements. The PFM signal comprises…
The extensive research and development of micromechanical resonators is trying to allow the use of these devices for highly sensitive applications. Microcantilevers are some of the simplest MEMS structure and had been proved to be a good…
A method to measure the viscosity of liquids at microscales is presented. It uses a thin glass fiber fixed on the tip of the cantilever of an extremely low noise Atomic Force Microscope (AFM), which accurately measures the cantilever…
A novel methodology for measuring gas flow from small orifices or nozzles into vacuum is presented. It utilizes a high-intensity femtosecond laser pulse to create a plasma within the gas plume produced by the nozzle, which is imaged by a…
Understanding airflow around a drone is critical for performing advanced maneuvers while maintaining flight stability. Recent research has worked to understand this flow by employing 2D and 3D flow sensors to measure flow from a single…
Eigen frequency is one of the most important system responses to be considered while designing a micro-scale piezoelectric cantilever beam. This paper investigates and analyzes the effect of dimension parameters of a micro-scale…
We present the design, fabrication, and response of a low-power, polymer-based VOC sensor based on the self-leveling of mechanically leveraged structures. The device utilizes folded polymer-coated microcantilevers to achieve passive…
A spreadsheet algorithm is given for the atomic force microscope that accounts for non-linear behavior in the deflection of the cantilever and in the photo-diode response. In addition, the data analysis algorithm takes into account…
We describe a method for feedback-regulation of a microcantilever's response using optical radiation pressure. One laser measures the position of the cantilever and another laser applies a force that is a phase-shifted function of that…
A microfluidic approach to probing the first normal stress difference from single-point pressure measurements in transient shear flows is presented. Using an original experimental design, we examine the near-zero-mean pulsatile flow of…
We consider the stochastic dynamics of an array of two closely spaced atomic force microscope cantilevers in a viscous fluid for use as a possible biomolecule sensor. The cantilevers are not driven externally, as is common in applications…
We present the findings from an experimental study of a MEMS flow sensor in which an initially curved, double-clamped bistable microbeam is the primary sensing element. Our research explores how the overheat ratio, direct flow loading, and…
Measurements of the deflection induced by thermal noise have been performed on a rectangular atomic force microscope cantilever in air. The detection method, based on polarization interferometry, can achieve a resolution of 1E-14 m/rtHz in…
We demonstrated selective gas sensing with MoS2 thin-film transistors using the change in the channel conductance, characteristic transient time and low-frequency current fluctuations as the sensing parameters. The back-gated MoS2 thin-film…
An aircraft's airspeed, angle of attack, and angle of side slip are crucial to its safety, especially when flying close to the stall regime. Various solutions exist, including pitot tubes, angular vanes, and multihole pressure probes.…
We measure the mechanical thermal noise of soft silicon atomic force microscopy cantilevers. Using an interferometric setup, we have a resolution down to 1E-14 m/rtHz on a wide spectral range (3 Hz to 1E5 Hz). The low frequency behavior…
The interrogation of a sensor based on a highly birefringent film irradiated by an incident beam whose polarization is oriented 45o with respect to the normal film axes is shown to display exceptional features and resolve some outstanding…
We report on the design, fabrication, and implementation of ultrasensitive micromechanical oscillators. Our ultrathin single-crystal silicon cantilevers with integrated magnetic structures are the first of their kind: They are fabricated…