中文
相关论文

相关论文: Improvement of measurement accuracy in SU(1,1) int…

200 篇论文

We theoretically investigate an interferometer composed of four four-wave-mixers by Lie group method. Lie group SU(1,2) characterizes the mode transformations of this kind of interferometer. With vacuum state inputs, the phase sensitivity…

量子物理 · 物理学 2015-12-15 Yadong Wu , Chun-Hua Yuan

We study the phase sensitivity of SU(2) and SU(1,1) interferometers fed by two-mode field states which are intelligent states for Hermitian generators of the SU(2) and SU(1,1) groups, respectively. Intelligent states minimize uncertainty…

量子物理 · 物理学 2009-10-30 C. Brif , A. Mann

An ${\rm SU(1,1)}$ interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field ${\rm SU(1,1)}$…

SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second…

量子物理 · 物理学 2021-04-07 Jian-Dong Zhang , Chenglong You , Chuang Li , Shuai Wang

Nonlinear SU(1,1) interferometers are fruitful and promising tools for spectral engineering and precise measurements with phase sensitivity below the classical bound. Such interferometers have been successfully realized in bulk and…

Multimode integrated interferometers have great potential for both spectral engineering and metrological applications. However, material dispersion of integrated platforms constitutes an obstacle which limits the performance and precision…

光学 · 物理学 2022-09-13 Alessandro Ferreri , Polina R. Sharapova

We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input…

To improve the phase sensitivity, multi-photon subtraction schemes within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of…

量子物理 · 物理学 2023-11-27 Q. Q. Kang , Z. K. Zhao , Y. K. Xu , T. Zhao , C. J. Liu , L. Y. Hu

Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the…

量子物理 · 物理学 2023-11-28 D. Scharwald , T. Meier , P. R. Sharapova

Although SU(1,1) interferometry achieves Heisenberg-limited sensitivities, it suffers from one major drawback: only those particles outcoupled from the pump mode contribute to the phase measurement. Since the number of particles outcoupled…

量子物理 · 物理学 2017-04-13 Stuart S. Szigeti , Robert J. Lewis-Swan , Simon A. Haine

The quantum correlation of light and atomic collective excitation can be used to compose an SU(1,1)-type hybrid light-atom interferometer, where one arm in optical SU(1,1) interferometer is replaced by the atomic collective excitation. The…

量子物理 · 物理学 2015-09-01 Hongmei Ma , Dong Li , Chun-Hua Yuan , L. Q. Chen , Z. Y. Ou , Weiping Zhang

An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel…

Absolute sensitivity is measured for the phase measurement in an SU(1,1) type interferometer and the results are compared to that of a Mach-Zehnder interferometer operated under the condition of the same intra-interferometer intensity. The…

量子物理 · 物理学 2022-02-02 Wei Du , Jun Jia , J. F. Chen , Z. Y. Ou , Weiping Zhang

We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses.…

量子物理 · 物理学 2026-05-22 Sonu Jana , Dhruv Baheti , Paul Grossiord , Fabien Bretenaker , Nadia Belabas , Syamsundar De

In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is…

量子物理 · 物理学 2017-12-06 Mathieu Manceau , Gerd Leuchs , Farid Khalili , Maria Chekhova

Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these…

量子物理 · 物理学 2024-11-15 Qingqian Kang , Zekun Zhao , Teng Zhao , Cunjin Liu , Liyun Hu

The precision of phase estimation with interferometers can be greatly enhanced using non-classical quantum states, and the SU(11) interferometer is an elegant scheme, which generates two-mode squeezed state internally and also amplifies the…

量子物理 · 物理学 2023-07-28 Mingchen Liu , Lijian Zhang , Haixing Miao

Multimode quantum light has promising applications in many areas of physics, such as quantum communications and quantum computing. However, its multimode nature also makes it challenging to measure its properties. Recently [Optica Quantum…

量子物理 · 物理学 2025-04-29 D. Scharwald , P. R. Sharapova

The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beamsplitters replaced with parametric nonlinear optical processes. We consider the cases of bright and vacuum-seeded SU(1,1) interferometers…

量子物理 · 物理学 2017-07-05 B. E. Anderson , B. L. Schmittberger , P. Gupta , K. M. Jones , P. D. Lett

We theoretically study the phase sensitivity of the SU(1,1) interferometer with a coherent light together with a squeezed vacuum input case using the method of homodyne. We find that the homodyne detection has better sensitivity than the…

量子物理 · 物理学 2014-08-26 Dong Li , Chun-Hua Yuan , Z. Y. Ou , Weiping Zhang
‹ 上一页 1 2 3 10 下一页 ›