相关论文: Beam extraction studies at 900 GeV using a channel…
A proof-of-principle experimental setup for the extraction of 6 GeV electrons from the DESY II Booster Synchrotron using the channeling effect in a bent crystal is elaborated. Various aspects of the experimental setup were investigated in…
The design and performance of a novel crystal deflector for proton beams are reported. A silicon crystal was used to channel and extract 70 GeV protons from the U-70 accelerator in Protvino with an efficiency of 85%, as measured for a beam…
New crystal technique - array of bent strips and a fan-type reflector, based on thin straight plates - have been used for research of extraction and collimation a circulating beam in the U-70 accelerator at the energy 50 GeV and 1.3 GeV. It…
In the Collider Run II, the Tevatron operates with 36 high intensity bunches of 980 GeV protons and antiprotons. Particles not captured by the Tevatron RF system pose a threat to quench the superconducting magnet during acceleration or at…
For the first time at the Beam Test Facility of the DA{\Phi}NE accelerator complex at the Laboratori Nazionali di Frascati of INFN, 450 MeV positrons have been deflected with high efficiency, using the Planar Channeling process in a bent…
The efficiency of the beam extraction and collimation systems in circular accelerators with the use of the channeling effect in a bent crystal is determined. The dependences of the extraction efficiency on the geometrical parameters of the…
A recent study [1] has introduced an advanced method aimed at extracting from a circular particle accelerator over millions of turns using stable islands and a bent crystal. This technique leverages the strength of non-linear beam dynamics…
Using channeling in a 5-mm crystal with bending angle of 0.65 mrad, a record high efficiency, over 60%, of particle extraction from accelerator was achieved. The extracted beam intensity was up to 5.2*10^11 protons per spill of 0.5 s…
Silicon crystal was channeling and extracting 70-GeV protons from the U-70 accelerator with efficiency of 85.3+-2.8% as measured for a beam of 10^12 protons directed towards crystals of 2 mm length in spills of 1-2 s duration. The…
Bent crystal situated in a circulating beam can serve for efficient slow extraction or active collimation of the beams. This technique, well established at 10-1000 GeV, could be efficient also at the energies as low as 0.1-10 GeV according…
An analytical theory for the efficiency of particle extraction from an accelerator by means of a bent crystal is proposed. The theory agrees with all the measurements performed in the broad energy range of 14 to 900 GeV, where the…
The new results of using short (2-4mm) bent crystals for extraction and collimation of proton beam at IHEP 70 Gev proton synchrotron are reported. A broad range of energies from 6 to 65 GeV has been studied in the same crystal collimation…
For almost a quarter of a century the Tevatron proton-antiproton collider was the centrepiece of the world's high-energy physics program, from the start of operation in December 1985 until it was overtaken by the LHC in 2011. The initial…
Basing on experiments at SLAC, MAMI, CERN, and on Monte Carlo simulations, we assess the physical limits on efficiency and reachable angles of electron deflection in bent crystals in the energy range from sub-GeV to sub-TeV. We find that…
Using a computer model for the crystal extraction, we investigate the bent-crystal parameters optimal for the extraction experiment. The optimal crystal curvature is found to be near 1 GeV/cm (for pv/R), i.e. a factor of 2--3 higher than…
Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. However, if…
The development of high gradient acceleration and tight phase-space control of high power beams is a key element for future lepton and hadron colliders since the increasing demands for higher energy and luminosity significantly raise costs…
IHEP Protvino has pioneered the wide practical use of bent crystals as optical elements in high-energy beams for beam extraction and deflection on permanent basis since 1989. In the course of IHEP experiments, crystal channeling has been…
This paper presents the physical background for particle extraction from IHEP accelerator using short bent silicon crystals, analyses the results of the studies, considers in detail the regime of simultaneous work of crystal extraction and…
This report overviews studies accomplished in the U70 proton synchrotron of IHEP-Protvino during the recent two decades. Major attention is paid to a routine application of bent crystals for beam extraction from the machine. It has been…