中文
相关论文

相关论文: Thin gap parallel mesh chamber: a sparkless high-r…

200 篇论文

A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution…

高能物理 - 实验 · 物理学 2007-05-23 V. Ammosov , V. Gapienko , A. Semak , V. Senko , Yu. Sviridov , V. Zaets , E. Usenko

In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically…

仪器与探测器 · 物理学 2009-11-07 P. Fonte , V. Peskov

Groove chambers with different pitch and gap height have been tested. Gas amplifications of the order of a few times 10$^{3}$ have been obtained. Combining a groove structure with a GEM pre-amplification foil a gas gain of 10$^{5}$ was…

核实验 · 物理学 2008-11-26 I. Reichwein , U. Werthenbach , G. Zech

In this work we present a novel idea for a compact spark-protected single amplification stage Micro-Pattern Gas Detector (MPGD). The detector amplification stage, realized with a structure very similar to a GEM foil, is embedded through a…

仪器与探测器 · 物理学 2015-06-23 G. Bencivenni , R. De Oliveira , G. Morello , M. Poli Lener

We describe a novel gaseous detector concept for heavy-ion tracking and imaging: the Optical Parallel-Plate Avalanche Counter (O-PPAC). The detector consists of two thin parallel-plate electrodes separated by a small (typically 3 mm) gap…

仪器与探测器 · 物理学 2018-10-17 Marco Cortesi , Yassid Ayyada , John Yurkon

We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad…

In this paper, the performances of a type of the domestic THGEM (THick Gaseous Electron Multiplier) working in the Ar/CO2 mixtures are reported in details. This kind of single THGEM can provide the gain range from 100 to 1000, which is very…

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Plasmonic terahertz detection by a double-grating gate field-effect transistor structure with an asymmetric unit cell is studied theoretically. Detection responsivity exceeding 8 kV/W at room temperature in the photovoltaic response mode is…

介观与纳米尺度物理 · 物理学 2015-06-03 V. V. Popov , D. V. Fateev , T. Otsuji , Y. M. Meziani , D. Coquillat , W. Knap

Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. The TGCs are expected to provide a trigger signal within 25 ns of the bunch spacing. An extensive system test of the ATLAS muon…

仪器与探测器 · 物理学 2016-11-18 Y. Benhammou , E. Etzion , S. Bressler , S. Tarem , D. Lellouch , L. Levinson

A position sensitive thin gap chamber has been developed. The position resolution was measured using the cosmic muons. This paper presents the structure of this detector, position resolution measurement method and results.

仪器与探测器 · 物理学 2015-06-17 Yanyan Du , Tongye Xu , Ruobin Shao , Xu Wang , Chengguang Zhu

In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial…

仪器与探测器 · 物理学 2020-09-07 Gábor Galgóczi , Gergő Hamar , Péter Pázmándi , Dezső Varga

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas…

Plasmonic detectors have the potential to provide a method of rapid spectroscopy without the need of moving mirrors or gratings. Previous measurements have demonstrated frequency tunable detection based on plasmonic excitations, however…

材料科学 · 物理学 2015-02-09 Che Jin Bae , Deepu George , Rohit Singh , Gottfried Strasser , Andrea Markelz

The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…

仪器与探测器 · 物理学 2015-10-28 Kiadtisak Saenboonruang , Piyakul Kumphiranon , Kittipong Kulasri , Anawat Ritthirong

Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors,…

The reduction of the average charge per count in the gas along with the capability to discriminate very small signals from noise can allow an efficient and long-term Resistive Plate Chamber detector operation in high radiation background…

仪器与探测器 · 物理学 2020-12-30 Luca Pizzimento

Experiments like ATLAS at the HL-LHC or detectors at future hadron colliders need muon detectors with excellent momentum resolution up to the TeV scale both at the trigger and offline reconstruction levels. This requires muon tracking…

Plasmonic detectors have the potential to provide a method of rapid spectroscopy without the need of moving mirrors or gratings. Previous measurements have demonstrated frequency tunable detection based on plasmonic excitations, however…

材料科学 · 物理学 2015-02-04 Che Jin Bae , Gottfried Strasser , Andrea G. Markelz