We have investigated the diffuse reflection probabilities of Replica guides for ultra-cold neutrons (UCN) using the so-called helium method. For the first time we could establish a consistent description of the diffuse reflection mechanism…

仪器与探测器 · 物理学 2017-01-27 S. Wlokka , P. Fierlinger , A. Frei , P. Geltenbort , S. Paul , T. Pöschl , F. Schmid , W. Schreyer , D. Steffen

Neutron guides are used to transport slow neutrons from sources to experiments. Conventional neutron supermirror guides use alternating thin layers based on nickel and titanium. Due to the magnetic properties of nickel, their neutron…

仪器与探测器 · 物理学 2022-04-20 A. Hollering , N. Rebrova , C. Klauser , Th. Lauer , B. Märkisch , U. Schmidt

For ultracold neutrons with a kinetic energy below 10 neV, strong scattering, characterized by $2\pi l_{c} / \lambda\leq 1$, can be obtained in metamaterials of C and $^7$Li. Here $l_{c}$ and $\lambda$ are the coherent scattering mean free…

仪器与探测器 · 物理学 2020-09-18 Zhehui Wang , Marcel Demarteau , C. L. Morris , Yanhua Shih

We report on the evaluation of commercial electroless nickel phosphorus (NiP) coatings for ultracold neutron (UCN) transport and storage. The material potential of 50~$\mu$m thick NiP coatings on stainless steel and aluminum substrates was…

Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However,…

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend…

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments…

We performed ultracold neutron (UCN) storage measurements to search for additional losses due to neutron (n) to mirror-neutron (n') oscillations as a function of an applied magnetic field B. In the presence of a mirror magnetic field B',…

Experimental data shows anomalously large Ultra Cold Neutrons (UCN) reflection losses and that the process of UCN reflection is not completely coherent. UCN anomalous losses under reflection cannot be explained in the context of neutron…

Ultracold neutrons (UCN) have very low kinetic energies 0-300 neV, thereby can be stored in specific material or magnetic confinements for many hundreds of seconds. This makes them a very useful tool in probing fundamental symmetries of…

仪器与探测器 · 物理学 2018-03-14 G. Zsigmond

We investigate neutron--antineutron oscillations of ultracold neutrons in a storage bottle represented by a one-dimensional potential. The experimental sensitivity is determined by the annihilation rate of antineutrons. Its dependence on…

高能物理 - 实验 · 物理学 2026-02-13 Hiroyuki Fujioka , Takashi Higuchi

Ultracold neutrons (UCN) are free neutrons that can be stored in experimental setups for several minutes. Some of the most important properties of the neutron, such as its tiny permanent electric dipole moment and its beta decay lifetime,…

核实验 · 物理学 2020-06-09 Klaus Kirch , Bernhard Lauss

Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example…

While the international nEDM collaboration at the Paul Scherrer Institut (PSI) took data in 2017 that covered a considerable fraction of the parameter space of claimed potential signals of hypothetical neutron ($n$) to mirror-neutron ($n'$)…

We study possibility of efficient reflection of very cold neutrons (VCN) from powders of nanoparticles. In particular, we measured the scattering of VCN at a powder of diamond nanoparticles as a function of powder sample thickness, neutron…

We report on successful tests of holographically arranged grating-structures in nanoparticle-polymer composites in the form of 100 microns thin free-standing films, i.e. without sample containers or covers that could cause unwanted…

材料科学 · 物理学 2015-06-04 J. Klepp , C. Pruner , Y. Tomita , K. Mitsube , P. Geltenbort , M. Fally

The most accurate neutron lifetime measurements now use the material or magnetic traps of ultracold neutrons (UCN). The precision of these experiments is determined by the accuracy of estimating the neutron loss rate. In material UCN traps…

Ultracold neutrons provide a unique tool for the study of neutron properties. An overview is given of the ultracold neutron (UCN) source at PSI, which produces the highest UCN intensities to fundamental physics experiments by exploiting the…

核实验 · 物理学 2021-06-08 Bernhard Lauss , Bertrand Blau

We have constructed a Doppler-shifter-type pulsed ultra-cold neutron (UCN) source at the Materials and Life Science Experiment Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). Very-cold neutrons (VCNs) with…

仪器与探测器 · 物理学 2016-01-20 S. Imajo , K. Mishima , M. Kitaguchi , Y. Iwashia , N. L. Yamada , M. Hino , T. Oda , T. Ino , H. M. Shimizu , S. Yamashita , R. Katayama