Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted…

High-precision Penning trap mass measurements on the stable nuclide 27Al as well as on the short-lived radionuclides 26Al and 38,39Ca have been performed by use of radiofrequency excitation with time-separated oscillatory fields, i.e.…

The technique of Penning trap mass spectrometry is briefly reviewed particularly in view of precision experiments on unstable nuclei, performed at different facilities worldwide. Selected examples of recent results emphasize the importance…

核实验 · 物理学 2009-09-24 K. Blaum , Sz. Nagy , G. Werth

Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap…

仪器与探测器 · 物理学 2009-01-16 D. Beck , K. Blaum , G. Bollen , P. Delahaye , S. George , C. Guenaut , F. Herfurth , A. Herlert , D. Lunney , L. Schweikhard , C. Yazidjian

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental…

The Penning-trap electronic-detection technique that offers the precision and sensitivity requested in mass spectrometry for fundamental studies in nuclear and particle physics has not been proven yet to be universal. This has motivated the…

A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its…

Phase-imaging ion-cyclotron-resonance technique has been implemented at the Penning-trap mass spectrometer JYFLTRAP and is routinely employed for mass measurements of stable and short-lived nuclides produced at IGISOL facility. Systematic…

仪器与探测器 · 物理学 2021-11-10 D. A. Nesterenko , T. Eronen , Z. Ge , A. Kankainen , M. Vilen

We propose a novel type of precision laser spectrometer for trapped, highly charged ions nearly at rest. It consists of a cylindrical open-endcap Penning trap in which an externally produced bunch of highly charged ions can be confined and…

原子物理 · 物理学 2009-11-11 M. Vogel , D. F. A. Winters , D. M. Segal , R. C. Thompson

The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving…

A new procedure to prepare isomerically clean samples of ions with a mass resolving power of more than 100,000 has been developed at the JYFLTRAP tandem Penning trap system. The method utilises a dipolar rf-excitation of the ion motion with…

Ramsey interferometry is a cornerstone technique for precise measurement of time and frequency in modern clocks. The Ramsey experiments are typically done in optically dilute samples of atoms to improve homogeneity and avoid back-action of…

量子物理 · 物理学 2025-05-20 S. A. Moiseev , K. I. Gerasimov , M. M. Minnegaliev , I. V. Brekotkin , E. S. Moiseev

In Penning traps electromagnetic forces are used to confine charged particles under well-controlled conditions for virtually unlimited time. Sensitive detection methods have been developed to allow observation of single stored ions. Various…

原子物理 · 物理学 2022-03-16 Klaus Blaum , Sergey Eliseev , Sven Sturm

At Central Michigan University we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP)that will focus on measurements with long-lived radioactive isotopes. CHIP-TRAP will consist of a pair of hyperbolic…

We use an electric-dipole laser-driven transition to precisely measure the cyclotron-frequency ratios of the pairs $^{42}$Ca$^+$-$^{40}$Ca$^+$, $^{44}$Ca$^+$-$^{40}$Ca$^+$ and $^{48}$Ca$^+$-$^{40}$Ca$^+$ in a 7-tesla Penning trap. A single…

The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut f\"ur Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy…

We have extended Ramsey spectroscopy by stepping the probe frequency during the two Ramsey excitation pulses to compensate frequency shifts induced by the excitation itself. This makes precision Ramsey spectroscopy applicable even for…

An exact generalization of the Ramsey transition probability is derived to improve ultra-high precision measurement and quantum state engineering when a particle is subjected to independently-tailored separated oscillating fields. The…

原子物理 · 物理学 2015-08-19 T. Zanon-Willette , V. I. Yudin , A. V. Taichenachev

We experimentally investigate a recently proposed optical excitation scheme [V.I. Yudin et al., Phys. Rev. A 82, 011804(R)(2010)] that is a generalization of Ramsey's method of separated oscillatory fields and consists of a sequence of…

原子物理 · 物理学 2012-11-27 N. Huntemann , B. Lipphardt , M. Okhapkin , Chr. Tamm , E. Peik , A. V. Taichenachev , V. I. Yudin

An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is…