相关论文: Measurement and simulation of the neutron response…
We investigate scintillation linearity of a commercial high pressure $^4$He gas detector using monoenergetic 2.8 MeV neutrons from a deuterium-deuterium fusion neutron generator. The scintillation response of the detector was measured for a…
The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks'…
Absolute measurements of neutron fluence are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. The H(n,p) elastic scattering cross section is a very…
The $^{235}$U(n,f) reaction cross section was measured relative to neutron-proton elastic scattering for the first time in the energy region from 10 MeV to 440 MeV at the CERN n\_TOF facility, extending the upper limit of the only previous…
We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured…
We present Monte Carlo (MC) simulation results from a study of a compact plastic-scintillator detector suitable for imaging fast neutrons in the 1 -- 10 MeV energy range: the miniTimeCube (mTC). Originally designed for antineutrino…
The emission of neutrons from heavy ion reactions is an important observable for studying the asymmetric nuclear equation of state and the reaction dynamics. A 20-unit neutron array has been developed and mounted on the compact spectrometer…
We describe the neutron polarimeter NPOL3 for the measurement of polarization transfer observables $D_{ij}$ with a typical high resolution of $\sim$300 keV at $T_n$ $\simeq$ 200 MeV. The NPOL3 system consists of three planes of neutron…
Measurements of neutron-induced fission cross sections and light-ion production are planned in the energy range 1-40 MeV at the upcoming Neutrons For Science (NFS) facility. In order to prepare our detector setup for the neutron beam with…
Differential cross sections for deuteron breakup $^{1}H(d, pp)n$ reaction were measured for a large set of 243 geometrical configurations at the beam energy of 80 MeV/nucleon. The cross section data are normalized by the luminosity factor…
In this paper, we report the measurement of the energy flow, the cross section and the average inelasticity of forward neutrons (+ antineutrons) produced in $\sqrt{s} = 13$ TeV proton-proton collisions. These quantities are obtained from…
Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid…
A new measurement is presented of the $^6$Li(n,$\alpha$)t cross section from 245 keV to 10 MeV using a $^{252}$Cf fission chamber with $^6$LiI(Eu) and Cs$_2$LiYCl$_6$:Ce (CLYC) scintillators which act as both target and detector. Neutron…
To study the dependence of the equation of state of high density nuclear matter on the term characterizing the isospin (proton-neutron) asymmetry of nuclear matter, it is necessary to measure azimuthal flow of neutrons as well as azimuthal…
We report a novel neutron-detection approach employing an EJ-309 liquid scintillator surrounded by six 3He proportional counters. Tests were performed at the FRANZ facility of the Goethe-University Frankfurt using the 7Li(p,n0)7Be reaction,…
The photo-neutron cross sections of $^{162,163}\rm{Dy}$ have been measured for the first time in an energy region from the neutron threshold ($S_n$) up to $\approx$ $13$~MeV. The ($\gamma$,n) reaction was induced with quasi-monochromatic…
The neutron elastic magnetic form factor GMn has been extracted from quasielastic electron scattering data on deuterium with the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. The kinematic coverage of the measurement is…
The neutron energy spectrum for energies between 5 and 15 MeV has been measured in the INFN Laboratori Nazionali del Gran Sasso in Italy, by using a $1.5~m^3$ stainless-steel tank filled with 1.2 ton Gd-doped liquid scintillator. A…
A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…
The miniBELEN detector is a moderated neutron counter based on the use of $^3$He tubes and high-density polyethylene as moderator. The detector has been designed to have a neutron detection efficiency that is nearly independent from the…