相关论文: Development of a two-dimensional virtual pixel X-r…
Gas Electron Multiplier (GEM) is one of the mostly used gaseous detectors in the High Energy Physics (HEP) experiments. GEMs are widely used as tracking devices due to their high-rate handling capability and good position resolution. An…
Spectroscopic measurements are presented using the PID350 pixelated gamma radiation detectors. A high-speed data acquisition system has been developed in order to reduce the data loss during the data reading in case of a high flux of…
In this paper, we propose an eXtended Virtual Element Method (X-VEM) for two-dimensional linear elastic fracture. This approach, which is an extension of the standard Virtual Element Method (VEM), facilitates mesh-independent modeling of…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…
A new radial time projection chamber based on Gas Electron Multiplier amplification layers was developed for the BONuS12 experiment in Hall B at Jefferson Lab. This device represents a significant evolutionary development over similar…
Refraction-enhanced x-ray radiography (REXR) is used to infer shock-wave positions of more than one shock wave, launched by a multiple-picket pulse in a planar plastic foil. This includes locating shock waves before the shocks merge, during…
Gas electron multiplier (GEM) is widely used in modern gas detectors of ionizing radiation in experiments on high-energy physics at accelerators and in other fields of science. Typically the GEM devices are based on a dielectric foil with…
DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise (ENC = 2.2e at room temperature) operation can be obtained by implementing the amplifying transistor in the pixel cell itself. Full…
The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…
Mechanical stress control is becoming one of the major challenges for the future of micro and nanotechnologies. Micro scanning X-ray diffraction is one of the promising techniques that allows stress characterization in such complex…
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX…
We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 $\times$ 7.5 $\times$ 15 cm), modular X-ray calorimeter made of…
A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…
A large volume Time Projection Chamber (TPC) has been proposed as main tracking device at the International Linear Collider (ILC). Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…
The low repetition rates and possible shot-to-shot variations in laser-plasma studies place a high value on single-shot diagnostics. For example, white-beam scattering methods based on broadband backlighter x-ray sources are used to…
The demands on detectors for particle detection as well as for medical and astronomical X-ray imaging are continuously pushing the development of novel pixel detectors. The state of the art in pixel detector technology to date are hybrid…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are…