We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental calibration of optical telescopes. The heart of…
A Time of Flight monitoring system has been developed for BES3. The light source is a 442-443 nm laser diode, which is stable and provides a pulse width as narrow as 50 ps and a peak power as large as 2.6 W. Two optical-fiber bundles with a…
The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation…
Visible-light long baseline interferometry holds the promise of advancing a number of important applications in fundamental astronomy, including the direct measurement of the angular diameters and oblateness of stars, and the direct…
The velocity of a ~3 GeV neutrino beam is measured by comparing detection times at the Near and Far detectors of the MINOS experiment, separated by 734 km. A total of 473 Far Detector neutrino events was used to measure (v-c)/c = 5.1 +/-…
We demonstrate a narrow-linewidth 780 nm laser system with up to 40 W power and a frequency modulation bandwidth of 230 MHz. Efficient overlap on nonlinear optical elements combines two pairs of phase-locked frequency components into a…
In experimental nuclear physics (NP), high-precision electromagnetic calorimetry typically requires a good energy resolution and linear photosensor response on the level of (1-2)% over a full dynamic range of the detector. The beam of…
We report the first measurement with no approximations of the full field of tightly focused vector beams (NA up to $1.23$) across areas of $\sim 9-49\,\lambda ^2$. Prior to focusing, the structured laser light has a linear or circular…
We describe an ultrafast time resolved pump-probe spectroscopy setup aimed at studying the switching of nanophotonic structures. Both fs pump and probe pulses can be independently tuned over broad frequency range between 3850 and 21050…
The NLC extraction line provides a secondary focal point with a low beta function and 2 cm dispersion which can be used for measurement of the beam energy spectrum. In this study, tracking simulations were performed to transport the 0.5 TeV…
An intense 146 MeV/c pion beam was stopped inside a scintillating fiber detector made out of 12 planes with 16 pixels each, where every pixel consists out of 8 times 8 scintillating fibers of 500 mkm diameter dense packed. The detector was…
Focused ion beams (FIBs) are widely used in nanofabrication for applications such as circuit repair, ultra-thin lamella preparation, strain engineering, and quantum device prototyping. Although the lateral spread of the ion beam is often…
The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…
To meet the stringent time calibration requirements for the Belle II experiment upgrade, particularly for its large-size KL and Muon Detector comprising tens of thousands of scintillator channels with time resolutions better than 100 ps, we…
A proton irradiation site for silicon detectors has been developed and commissioned at the Bonn Isochronous Cyclotron. The accelerator provides 14 MeV proton beams of up to 1 $\mu$A at beam widths of a few mm to the setup. Devices Under…
A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 {\mu}m (vertical x…
Today's high-intensity laser facilities produce short pulses can, in tight focus, reach peak intensities of $10^{22}\,\mathrm{Wcm}^{-2}$ and, in long focus, wakefield-accelerate electrons to GeV energies. The radiation-reaction--dominated…
The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the…
Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…