中文
相关论文

相关论文: A High Granularity Imaging Calorimeter for Cosmic-…

200 篇论文

The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010-2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the…

仪器与探测器 · 物理学 2023-10-02 ALICE Collaboration

The measurement of energy is a fundamental tool used, for example, in exploring the early universe, characterizing particle decay processes, as well as in quantum technology and computing. Some of the most sensitive energy detectors are…

Special calorimeters are needed to instrument the very forward region of an ILC detector. These devices will improve the hermeticity being important for new particle searches. A luminometer is foreseen to measure the rate of low angle…

仪器与探测器 · 物理学 2009-02-20 W. Lohmann

A precision measurement of the cosmic-ray positron spectrum may help to solve the puzzle of the nature of dark matter. Pairwise annihilation of neutralinos, predicted by some supersymmetric extensions to the standard model of particle…

天体物理仪器与方法 · 物理学 2010-02-17 H. Gast , R. Greim , T. Kirn , G. Roper Yearwood , S. Schael

The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number…

仪器与探测器 · 物理学 2009-11-13 M. Barbi

We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'',…

The motivation for PF calorimetry is to experimentally measure the energy of hadron jets with excellent resolution. In particle flow designs, sigma(E)/E < 5% should be possible for a range of jet energies from 50 GeV to 250 GeV, important…

仪器与探测器 · 物理学 2022-07-20 Randal Ruchti , Katja Kruger

A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here…

仪器与探测器 · 物理学 2014-11-20 C. Adloff , Y. Karyotakis , J. Repond , J. Yu , G. Eigen , Y. Mikami , N. K. Watson , J. A. Wilson , T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Ribon , V. Uzhinskiy , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , G. C. Blazey , D. Chakraborty , A. Dyshkant , K. Francis , D. Hedin , J. G. Lima , V. Zutshi , J. -Y. Hostachy , K. Krastev , L. Morin , N. D'Ascenzo , U. Cornett , D. David , R. Fabbri , G. Falley , K. Gadow , E. Garutti , P. Göttlicher , T. Jung , S. Karstensen , A. -I. Lucaci-Timoce , B. Lutz , N. Meyer , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , A. Vargas-Trevino , N. Wattimena , O. Wendt , N. Feege , M. Groll , J. Haller , R. -D. Heuer , S. Morozov , S. Richter , J. Samson , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , E. J. Kim , G. Kim , D-W. Kim , K. Lee , S. C. Lee , K. Kawagoe , Y. Tamura , P. D. Dauncey , A. -M. Magnan , H. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , M. G. Green , F. Salvatore , M. Bedjidian , R. Kieffer , I. Laktineh , M. -C. Fouz , D. S. Bailey , R. J. Barlow , M. Kelly , R. J. Thompson , M. Danilov , E. Tarkovsky , N. Baranova , D. Karmanov , M. Korolev , M. Merkin , A. Voronin , A. Frey , S. Lu , K. Seidel , F. Simon , C. Soldner , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , M. Faucci Giannelli , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , G. Gaycken , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , A. Rougé , M. Ruan , J-Ch. Vanel , H. Videau , K-H. Park , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , M. Belmir , S. W. Nam , I. H. Park , J. Yang , Jong-Seo Chai , Jong-Tae Kim , Geun-Bum Kim , J. Kang , Y. -J. Kwon

The CALICE collaboration is developing an engineering prototype of an analog hadron calorimeter for a future linear collider detector. The prototype has to prove the feasibility of building a realistic detector with fully integrated…

仪器与探测器 · 物理学 2019-08-13 Oskar Hartbrich , Mark Terwort

This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…

仪器与探测器 · 物理学 2016-01-11 Elysée Obame Ndong , Olivier Gallot-Lavallée , Frédéric Aitken

The CALICE collaboration has constructed a hadronic sandwich calorimeter prototype with 7608 scintillating plates, individually read out by multi-pixel silicon photomultipliers (SiPMs). For the first time ever the read out is performed…

仪器与探测器 · 物理学 2009-02-10 Riccardo Fabbri

The International Linear Collider (ILC) is a proposed electron-positron collider with a center-of-mass energy of 500~GeV, and a peak luminosity of $2 \cdot 10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$. The ILC will complement the Large Hadron…

加速器物理 · 物理学 2010-10-29 Iftach Sadeh

The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of…

The measurement of cosmic-ray individual spectra provides unique information regarding the origin and propagation of astro-particles. Due to the limited acceptance of current space experiments, protons and nuclei around the "knee" region…

The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by…

仪器与探测器 · 物理学 2016-10-10 Aliakbar Ebrahimi

Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the pi+ -> pi0 e+ nu decay rate are reported. Seventy-four individual crystals, polished and wrapped in Teflon foil, were…

A new method for calibrating the hadron response of a segmented calorimeter is developed. It is based on a principal component analysis of the calorimeter layer energy deposits, exploiting longitudinal shower development information to…

仪器与探测器 · 物理学 2019-08-14 Karl-Johan Grahn

A highly granular electromagnetic calorimeter prototype based on tungsten absorber and sampling units equipped with silicon pads as sensitive devices for signal collection is under construction. The full prototype will have in total 30…

仪器与探测器 · 物理学 2007-05-23 G. Mavromanolakis