相关论文: The BaBar Calorimeter Light Pulser System
The electro-magnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13…
The Crystal Barrel is an electromagnetic calorimeter consisting of 1380 CsI(Tl) scintillators, and is currently installed at the CBELSA/TAPS experiment where it is used to detect decay products from photoproduction of mesons. The readout of…
We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…
Pulsed UV lasers can provide useful "testbeams" for observatories that use optical detectors, especially fluorescence detectors, to measure high energy cosmic-rays. The light observed by the detector is proportional to the energy of the…
The International Linear Collider (ILC) is a proposed electron-positron collider with a center-of-mass energy of 500~GeV, and a peak luminosity of $2 \cdot 10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$. The ILC will complement the Large Hadron…
The electromagnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with high resolution. The current status of the calorimeter, now in its seventh year…
Purpose: Luminosity measurement at the Circular Electron-Positron Collider (CEPC) is required to achieve 10^-4 precision when operating at the center-of-mass energy of the Z-pole. Approximately 10^12 Z-bosons will be collected to refine…
We have built and tested a compact, low-cost, but very-high-performance astronomical polarimeter based on a continuously rotating half-wave plate and a high-speed imaging detector. The polarimeter is suitable for small telescopes up to ~1 m…
A photomultiplier setup for precise relative CsI(Tl) crystal light yield and uniformity measurements is described. It is used for wrapping material studies to optimize the uniformity and the yield of the light output of 36 cm long crystals.…
The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…
This paper describes the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification…
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…
The Very Large Area Gamma-ray Space Telescope Pathfinder (VLAST-P), as the technology validation satellite for the VLAST mission, is designed to observe high-energy solar bursts on orbit. The CsI electromagnetic calorimeter (ECAL) is one of…
Special calorimeters are needed to instrument the very forward region of an ILC detector. These devices will improve the hermeticity being important for new particle searches. A luminometer is foreseen to measure the rate of low angle…
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify…
Since May 1999 the BABAR detector has been taking data at the PEP-II asymmetric electron-positron collider at the Stanford Linear Accelerator Center, California. This experiment requires a very large data sample and the PEP-II accelerator…
Energy resolution is an important figure of merit for TES microcalorimeter. We propose a laser system to measure the energy resolution of TES microcalorimeter with a 1550 nm laser source. Compared to method that characterizes the…
A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact…
There is a growing interest in astrophysics to fill in the observational gamma-ray MeV gap. We, therefore, developed a CsI:Tl calorimeter prototype as a subsystem to a balloon-based Compton and Pair-production telescope known as ComPair.…
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated…