相关论文: Beam Current Monitors in the Nlcta
The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the current instantaneous luminosity by a factor of 5 to 7, providing the opportunity to study rare processes and measure precisely the standard model…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The intensity of charged particle beams at Fermilab must be kept within pre-determined safety and operational envelopes in part by assuring all beam within a few percent has been transported from any source to destination. Beam intensity…
The main role of the ITER Radial Neutron Camera (RNC) diagnostic is to measure in real-time the plasma neutron emissivity profile at high peak count rates for a time duration up to 500 s. Due to the unprecedented high performance conditions…
Neutron beam monitors are an essential diagnostic component of neutron scattering facilities. They are used to measure neutron flux, calibrating experiments performed on the instruments, allowing measurement of facility performance,…
Millimeter-wave (mmWave) technology is increasingly recognized as a pivotal technology of the sixth-generation communication networks due to the large amounts of available spectrum at high frequencies. However, the huge overhead associated…
The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in…
We have found experimentally that the rise times of voltage pulses in NbN superconducting single photon detectors increase nonlinearly with increasing detector length. We fabricated superconducting single photon detectors based on NbN thin…
We describe a study of high-energy Compton beam polarimeters for the future e+e- linear collider machine TESLA. A segment of the beam delivery system has been identified, which is aligned with the e+e- collision axis and which has a…
The paper proposes a method of finding the beam loss locations in a linac. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync produces a line at the…
Using the Gamma ray Burst Monitor (GBM) on Fermi we are monitoring accreting pulsar systems. We use the rates from GBM's 12 NaI detectors in the 8-50 keV range to detect and monitor pulsations with periods between 0.5 and 1000 seconds.…
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…
A fully digital beam position and phase measurement (BPPM) system was designed for the linear accelerator (LINAC) in Accelerator Driven Sub-critical System (ADS) in China. Phase information is obtained from the summed signals from four…
The measurement of the betatron tunes in a circular accelerator is of paramount importance due to their impact on beam dynamics. The resolution of the these measurements, when using turn by turn (TbT) data from beam position monitors…
In this paper, beam diagnostic and monitoring tools developed by the MAX IV Operations Group are discussed. In particular, new beam position monitoring and accelerator tunes visualization software tools, as well as tools that directly…
A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…
We report the design, operation, and performance of a next generation high-speed data acquisition system for multi-channel infrared and optical photometry based on the modern technologies of Field Programmable Gate Arrays, the Peripheral…
We present high signal-to-noise ratio, multi-frequency polarization pulse profiles for 24 millisecond pulsars that are being observed as part of the Parkes Pulsar Timing Array (PPTA) project. The pulsars are observed in three bands, centred…
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different…
With the rising volume of railroad transportation, the traditional track inspection mainly relies on manual inspection and large-scale inspection equipment, which not only has low inspection frequency and lagging response, but also has the…