GRAND is an array of position sensitive proportional wire chambers (PWCs) located at 86.2 degrees W, 41.7 degrees N at an elevation of 220 m adjacent to the campus of the University of Notre Dame with 82 square meters of total muon detector…

天体物理学 · 物理学 2008-07-16 J. Poirier , C. D'Andrea , E. Fidler , J. Gress , M. Herrera , P. Hemphill , C. Swartzendruber

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

The design of a detector based on MICROMEGAS (MICRO MEsh GAseous Structure) technology is presented. Our detector is characterized by a large active area of 398(\times)281 mm(^{2}), a pad read-out with 20(\times)22 mm(^{2}) segmentation,…

仪器与探测器 · 物理学 2016-08-15 L. Aphecetche , H. Delagrange , D. G. d'Enterria , M. Le Guay , X. Li , G. Martínez , M. J. Mora , P. Pichot , D. Roy , Y. Schutz

In this paper, the design and the performance of a prototype detector based on MicroMegas technology with two detection planes in a common gas volume is discussed. The detector is suited for the forward region of LHC detectors, addressing…

仪器与探测器 · 物理学 2017-06-28 Bernard Brickwedde , Andreas Düdder , Matthias Schott , Eda Yildirim

A set of classical multi-wire proportional chambers were designed and constructed with the main purpose of efficient cosmic muon detection. These detectors are relatively simple to construct, and at the same time are low cost, making them…

仪器与探测器 · 物理学 2015-09-30 Dezső Varga , Zoltán Gál , Gergő Hamar , Janka Sára Molnár , Éva Oláh , Péter Pázmándi

Portable and cost-effective gas sensors are gaining demand for a number of environmental, biomedical and industrial applications, yet current devices are confined into specialized labs and cannot be extended to general use. Here, we…

仪器与探测器 · 物理学 2020-04-10 Giuseppe Antonacci , Jeroen Goyvaerts , Haolan Zhao , Bettina Baumgartner , Bernhard Lendl , Roel Baets

A centenary after the invention of the basic principle of gas amplification, gaseous detectors - are still the first choice whenever the large area coverage with low material budget is required. Advances in photo-lithography and…

仪器与探测器 · 物理学 2013-08-16 Maxim Titov

We present the results of the measurements of the detection efficiency for a 4.7 \r{A} neutron beam incident upon a detector incorporating a stack of up to five MultiWire Proportional Counters (MWPC) with Boron-coated cathodes. The cathodes…

仪器与探测器 · 物理学 2015-06-17 I. Stefanescu , Y. Abdullahi , J. Birch , I. Defendi , R. Hall-Wilton , C. Hoglund , L. Hultman , M. Zee , K. Zeitelhack

The development of gaseous detectors has been exciting again since the appearance of a MicroStrip Gas Chamber(MSGC) in 1988, which is made using a micro-electronics technology. These days lots of variations of the advanced gaseous detectors…

高能物理 - 实验 · 物理学 2009-10-31 Toru Tanimori , Yuji Nishi , Atsuhiko Ochi , Yasuro Nishi

The requirement of high rate capability for operation at LHC, led 20 years ago to the achievement of Resistive Plate Chambers operated in avalanche mode, thanks to the introduction of new gas mixtures and to the development of the Front-End…

仪器与探测器 · 物理学 2017-06-28 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33 +/- 0.03,…

仪器与探测器 · 物理学 2015-06-26 J. K. Black , P. Deines-Jones , S. E. Ready , R. A. Street

The development of CdZnTe detectors with an orthogpnal coplanar anode structure has important implications for future astrophysical instrumentation. As electron-only devices, like pixel detectors, coplanar anode strip detectors can be…

天体物理学 · 物理学 2009-11-06 M. L. McConnell , L. A. Hamel , J. R. Macri , M. McClish , J. R. Ryan

The Spherical Proportional Counter is a novel type of radiation detector, with a low energy threshold (typically below 100 eV) and good energy resolution. This detector is being developed by the network NEWS, which includes several…

仪器与探测器 · 物理学 2015-01-09 F. J. Iguaz , A. Rodriguez , J. F. Castel , I. G. Irastorza

Results obtained with a new very compact detector for imaging with a matrix of Leak Microstructures (LM)are reported. Spatial linearity and spatial resolution obtained by scanning as well as the detection of alpha particles with 100%…

仪器与探测器 · 物理学 2020-09-18 M. Lombardi , G. Balbinot , A. Battistella , P. Colautti , V. Conte , L. De Nardo , G. Galeazzi , G. Prete , A. Ferretti

The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search…

仪器与探测器 · 物理学 2008-12-18 A. Bondar , A. Buzulutskov , A. Grebenuk , D. Pavlyuchenko , Y. Tikhonov

Physical principles of performance and main characteristics of a novel avalanche photodetector developed on the basis of MOS(metal-oxide-silicon) technology is presented. The photodetector contains a semitransparent gate electrode and a…

高能物理 - 实验 · 物理学 2007-05-23 Z. Ya. Sadygov , M. K. Suleimanov , T. Yu. Bokova

We present a new design and assembly procedure of a large-area gas-avalanche Resistive-Plate WELL (RPWELL) detector. A $50\times50 ~\mathrm{cm^2}$ prototype was tested in $\mathrm{80 ~GeV/c}$ muon beam at CERN-SPS, presenting improved…

仪器与探测器 · 物理学 2023-07-19 D. Zavazieva , L. Moleri , A. Jash , G. Sela , F. de Vito-Halevy , S. Bressler

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…

仪器与探测器 · 物理学 2011-07-19 M. S. Dixit , J. Dubeau , J. -P. Martin , K. Sachs

We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and…

仪器与探测器 · 物理学 2015-05-18 P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

The wire scanners are used for a measurement of the very small beam size and the emittance in Accelerator Test Facility (ATF). They are installed in the extraction beam line of ATF damping ring. The extracted beam emittance are ex=1.3x10-9…

加速器物理 · 物理学 2007-05-23 H. Hayano