中文
相关论文

相关论文: CMD-2 Detector Upgrade

200 篇论文

The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of…

仪器与探测器 · 物理学 2015-06-18 M. De Gerone , F. Gatti , W. Ootani , Y. Uchiyama , M. Nishimura , S. Shirabe , P. W. Cattaneo , M. Rossella

The brief history, physics program and the current status of the SVD-2 detector is presented. The future plans for the experiments with upgraded SVD-2M setup is discussed.

高能物理 - 实验 · 物理学 2007-05-23 P. Ermolov , A. Kiriakov , A. Kubarovsky , V. Nikitin , V. Popov , I. Rufanov , L. Tikhonova , V. Volkov , A. Vorobiev

The D0 Detector at Fermilab is currently undergoing an extensive upgrade to participate in the Run II data taking which shall begin on March 1, 2001. The design of the detector meets the requirements of the high luminosity environment…

高能物理 - 实验 · 物理学 2017-08-23 Neeti Parashar

After the Large Hadron Collider (LHC) upgrade into High Luminosity LHC (HL-LHC), the instantaneous luminosity is expected to reach values up to 7.5x10^34cm^2/s, causing a harsher radiation environment as well as a significant increase in…

仪器与探测器 · 物理学 2026-05-07 Giorgia Bonomelli

The muon system of the CMS experiment is expected to upgrade all of its subdetectors for the Phase-2 of the Large Hadron Collider (LHC) that will begin in 2029. The upgrade plans for drift tubes (DTs), cathode strip chambers (CSCs) and…

仪器与探测器 · 物理学 2023-12-19 Antonello Pellecchia

A second major LHCb detector upgrade will be installed during long shutdown 4 (LS4) of the CERN Large Hadron Collider. The new detector will provide excellent performance for studies of Quantum Chromodynamics at high temperature and…

高能物理 - 实验 · 物理学 2025-04-01 LHCb collaboration

The general purpose D0 collider detector at the Fermilab Tevatron has undergone major upgrades for Run II. We describe the current status and performance of the D0 detector.

高能物理 - 实验 · 物理学 2009-11-07 Levan Babukhadia

The status of VEPP-2000 collider is presented. Implementation of Round Colliding Beams (RCB) concept in the new collider VEPP-2000 is outlined, potential advantages of RCB over the flat colliding beams are discussed. The main design…

加速器物理 · 物理学 2007-05-23 I. A. Koop

The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…

仪器与探测器 · 物理学 2011-10-11 N. Parashar

The D0 detector at The Fermilab Tevatron is undergoing a major upgrade to prepare for data taking with luminosities reaching 2 x 10^{32} cm^{-2} s^{-1}. The upgrade includes a new central tracking array, new muon detector components and…

高能物理 - 实验 · 物理学 2007-05-23 P. Petroff

CMOS Pixel Sensors are making steady progress towards the specifications of the ILD vertex detector. Recent developments are summarised, which show that these devices are close to comply with all major requirements, in particular the…

The CMS inner pixel detector system is planned to be replaced during the first phase of the LHC luminosity upgrade. The plans foresee an ultra low mass system with four barrel layers and three disks on either end. With the expected increase…

仪器与探测器 · 物理学 2019-08-13 Carlotta Favaro

The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a center-of-mass energy of 14 TeV and to reach the unprecedented peak instantaneous luminosity of $7.5 \times 10^{34} \text{cm}^{-2} \text{s}^{-1}$…

仪器与探测器 · 物理学 2023-01-26 Sascha Liechti

The Belle II experiment at KEK in Japan considers upgrading its vertex detector system to address the challenges posed by high background levels caused by the increased luminosity of the SuperKEKB collider. One proposal for upgrading the…

The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced…

仪器与探测器 · 物理学 2010-01-25 H. C. Kästli

New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…

The demands on detectors for particle detection as well as for medical and astronomical X-ray imaging are continuously pushing the development of novel pixel detectors. The state of the art in pixel detector technology to date are hybrid…

仪器与探测器 · 物理学 2009-11-11 Hans Krueger

COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1.…

We present a report of the MEG II experiment, the upgrade of MEG, whose goal is to search for the forbidden decay \megc\ with increased precision. After having briefly reviewed the motivation for such a search and the current limit due to…

仪器与探测器 · 物理学 2017-08-02 P. W. Cattaneo