中文
相关论文

相关论文: Large-Area Scintillator Hodoscope with 50 ps Timin…

200 篇论文

A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…

仪器与探测器 · 物理学 2016-05-23 P. W. Cattaneo , M. De Gerone , F. Gatti , M. Nishimura , W. Ootani , M. Rossella , S. Shirabe , Y. Uchiyama

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

仪器与探测器 · 物理学 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

To meet the stringent time calibration requirements for the Belle II experiment upgrade, particularly for its large-size KL and Muon Detector comprising tens of thousands of scintillator channels with time resolutions better than 100 ps, we…

仪器与探测器 · 物理学 2026-02-23 Ziyu Liu , Xiyang Wang , Shiming Zou , Xiaolong Wang , Junhao Yin , Minggang Zhao

This paper describes the development of a threshold type aerogel Cherenkov counter with a large sensitive area of 0.6 m$^2$ to be carried onboard the BESS rigidity spectrometer to detect cosmic-ray antiprotons. The design incorporates a…

高能物理 - 实验 · 物理学 2009-10-31 Y. Asaoka , K. Abe , K. Yoshimura , M. Ishino , M. Fujikawa , S. Orito

We have tested a prototype time-of-flight system based on bulk scintillator block of dimensions $2.5 \times 2.5 \times 200$ cm. Using a calibration scheme similar to the one used in actual collider experiments, we have achieved a resolution…

高能物理 - 实验 · 物理学 2007-05-23 E. Chen , M. Saulnier , W. Sun , H. Yamamoto

In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…

仪器与探测器 · 物理学 2015-05-28 A. Stoykov , R. Scheuermann , K. Sedlak

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon…

The barrel time-of-flight detector for the PANDA experiment at FAIR is foreseen as a Scintillator Tile (SciTil) Hodoscope based on several thousand small plastic scintillator tiles read-out with directly attached Silicon Photomultipliers…

仪器与探测器 · 物理学 2019-08-14 L. Gruber , S. E. Brunner , J. Marton , H. Orth , K. Suzuki

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

The barrel time-of-flight (TOF) detector for the PANDA experiment at FAIR in Darmstadt is planned as a scintillator tile hodoscope (SciTil) using 8000 small scintillator tiles. It will provide fast event timing for a software trigger in the…

仪器与探测器 · 物理学 2015-06-18 S. E. Brunner , L. Gruber , J. Marton , H. Orth , K. Suzuki

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…

Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…

仪器与探测器 · 物理学 2021-09-08 Alexey Stoykov , Tigran Rostomyan

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

The performance of several trigger counters based on plastic scintillators with silicon photomultiplier readout is investigated with cosmic rays. Efficiency and time resolution are measured using digital waveform analysis. The obtained…

In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1…

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

仪器与探测器 · 物理学 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

The proven radiation hardness of silicon 3D devices up to fluences of $1 {\times} 10^{17}$ $n_{eq}/cm^{2}$ makes them an excellent choice for next generation trackers, providing < 10 ${\mu}m$ position resolution at a high multiplicity…

仪器与探测器 · 物理学 2024-03-05 Evangelos-Leonidas Gkougkousis , Edgar Lemos Cid , Viktor Coco
‹ 上一页 1 2 3 10 下一页 ›