相关论文: Transient stability of a power system with superco…
A superconducting fault current limiter of the transformer type (inductive FCL) based on magnetic coupling between a superconducting element and a protected circuit has been investigated by many authors for various parameters and…
Transient stability is a complex phenomenon presented in multi-machine and multi-converter systems, and it is still considered a key limiting factor for stressed power systems. The increasing integration of non-synchronous generation…
Grid forming control applied to power converters that interface storage or renewable generation to the power grid, has been identified as a potential solution to facilitate a substantial share of converter-based renewable generation in the…
Transients of a grid-synchronized voltage source converter (VSC) are closely related to over- currents and voltages occurred under large disturbances (e.g. a grid fault). Previous analysis in evaluating these transients usually neglect the…
In the past few years there has been a significant rise in the short-circuit current levels in transmission and distribution networks, it due to the increasing demands on power and the addition of sources of distributed generations. It…
Short circuit fault currents are increasing due to growing demand for electricity and high complexity in power systems. Because the fault currents reach the highest value which the breakers are unable to restrict, the electrical grid…
Numerous proposed and developed superconducting fault current limiters and self-limiting transformers limit successfully fault currents but do not provide uninterrupted supplying of consumers. A design investigated in the work combines the…
Superconducting fault current limiters (SFCLs) are new high-precision and fast-response devices which help to reduce the fault current within the breaking capacity of the protective relays. Nevertheless, the reconfigurable structure of the…
The increase of current uniformity along of a resistive type superconductor fault current limiter (R-SFCL) in the design of this type of limiters is well perceived as an important issue. The non-uniform distribution of current in R-SFCL…
Integrating grid-forming converters (GFMCs) into grid-following converter (GFLC)-dominated power systems enhances the grid strength, but GFMCs' current-limiting characteristic triggers dynamic switching between constant voltage control…
Deploying synchronous condensers (SynCons) near grid-following renewable energy sources (GFLRs) is an effective and increasingly adopted strategy for grid support. However, the potential transient instability risks in such configurations…
We have developed a computer model for the simulation of resistive superconducting fault current limiters in three dimensions. The program calculates the electromagnetic and thermal response of a superconductor to a time-dependent overload…
VSG control has emerged as a crucial technology for integrating renewable energy sources. However, renewable energy have limited tolerance to overcurrent, necessitating the implementation of current limiting (CL)strategies to mitigate the…
We present general principles of the parameters calculation and application of two power devices: an inductive fault current limiter and a current-limiting transformer. Both the devices are based on the superconducting - normal state…
Power systems, including synchronous generator systems, are typical systems that strive for stable operation. In this article, we numerically study the fault transient process of a synchronous generator system based on the first benchmark…
The use of distributed generation resources, in addition to considerable benefits, causes some problems in the power system. One of the most critical problems in the case of disruption is increasing short-circuit current level in grids,…
Large-scale integration of inverter-based resources into power grids worldwide is challenging their stability and security. This paper takes a closer look at synchronous condensers as a solution to mitigate stability challenges caused by…
With the increased penetration of renewable energy and reduced proportion of synchronous generators, the low-inertia characteristics of todays power system become prominent, and the transient stability issue of grid following converter…
Differing from synchronous generators, there are lack of physical laws governing the synchronization dynamics of voltage-source converters (VSCs). The widely used phase-locked loop (PLL) plays a critical role in maintaining the synchronism…
We reveal obstacles related to the application of HTS cylinders in current limiting devices based on the superconducting - normal state transition. It is shown that, at the critical current density achieved presently in bulk materials, and…