相关论文: A search for changing-look AGN in the Grossan cata…
We present $NuSTAR$ X-ray observations of the active galactic nucleus (AGN) in NGC 7674. The source shows a flat X-ray spectrum, suggesting that it is obscured by Compton-thick gas columns. Based upon long-term flux dimming, previous work…
We present the multi-epoch monitoring with NuSTAR and XMM-Newton of NGC 1358, a nearby Seyfert 2 galaxy whose properties made it a promising candidate X-ray changing look AGN, i.e., a source whose column density could transition from its…
(abridged)The majority of Active Galactic Nuclei (AGN) suffer from significant obscuration by surrounding dust and gas. X-ray surveys in the 2-10 keV band will miss the most heavily-obscured AGN in which the absorbing column density exceeds…
We present a detailed analysis of the X-ray spectrum of the Seyfert 2 galaxy NGC454E, belonging to the interacting system NGC454. Observations performed with Suzaku, XMM-Newton and Swift allowed us to detect a dramatic change in the…
We present results from a ~55 ks long XMM-Newton observation of the obscured AGN, NGC 5643, performed in July 2009. A previous, shorter (about 10 ks) XMM-Newton observation in February 2003 had left two major issues open, the nature of the…
We present a sample of twenty-one ROSAT bright active galactic nuclei (AGN), representing a range of spectral classes, and selected for follow-up snap-shot observations with XMM-Newton. The typical exposure was between 5-10 ks. The objects…
Type 2 active galactic nuclei (AGN) show signatures of accretion onto a supermassive black hole through strong, high-ionization, narrow emission lines extended on scales of 100s to 1000s of parsecs, but they lack the broad emission lines…
Active galactic nuclei (AGN) are known to be variable sources across the entire electromagnetic spectrum, in particular at optical/ultraviolet and X-ray energies. Over the past decades, a growing number of AGN have displayed type…
The presence of an obscuring torus at pc-scale distances from the central black hole is the main ingredient for the Unified Model of Active Galactic Nuclei (AGN), as obscured sources are thought to be seen through this structure. However,…
We present the results of five NuSTAR observations of the type 2 active galactic nucleus (AGN) in IC 751, three of which were performed simultaneously with XMM-Newton or Swift/XRT. We find that the nuclear X-ray source underwent a clear…
We report the detection of high-amplitude X-ray flaring of the AGN HE 1136-2304, which is accompanied by a strong increase in the flux of the broad Balmer lines, changing its Seyfert type from almost type 2 in 1993 down to 1.5 in 2014. HE…
We present a NuSTAR and XMM-Newton monitoring campaign in 2014/2015 of the Compton-thick Seyfert 2 galaxy, NGC 1068. During the August 2014 observation, we detect with NuSTAR a flux excess above 20 keV ($32\pm6 \%$) with respect to the…
We present XMM-Newton observations of three AGN taken as part of a hunt to find very heavily obscured Compton-thick AGN. For obscuring columns greater than 10^25 cm^-2, AGN are only visible at energies below 10 keV via reflected/scattered…
XMM-Newton spectra of five red, 2MASS AGN, selected from a sample observed by Chandra to be relatively X-ray bright and to cover a range of hardness ratios, confirm the presence of substantial absorbing material in three sources with…
This paper presents the analysis of a statistically complete sample of 28 serendipitous X-ray sources selected in 82 pointed XMM-Newton fields down to a count-rate of 0.002 counts s^-1(4.5-7.5 keV energy band). This is the first sample…
Active galactic nuclei (AGN) showing dramatic spectral and flux variations, either due to changes in the accretion rate (changing-state, CS-AGN) of the supermassive black hole or in the line-of-sight column density (changing-obscuration,…
(Abridged) We analyzed the {\it Chandra} and {\it XMM-Newton} archival observations for 72 type 2 quasars at $z<1$. These objects were was selected based on the [O III]$\lambda$5007 optical emission line which we assume to be an approximate…
We present optical and X-ray data for a sample of serendipitous XMM-Newton sources that are selected to have 0.5-2 keV vs 2-4.5 keV X-ray hardness ratios which are harder than the X-ray background. The sources have 2-4.5 keV X-ray flux >=…
We present results from an XMM-Newton observation of the nearby Seyfert 2 galaxy NGC5643. The nucleus exhibits a very flat X-ray continuum above 2 keV, together with a prominent K-alpha fluorescent iron line. This indicates heavy…
This paper presents the results of a study of X-ray spectral and flux variability on time scales from months to years, of the 123 brightest objects (including 46 type-1 AGN and 28 type-2 AGN) detected with XMM-Newton in the Lockman Hole…