中文
相关论文

相关论文: A WIMP Detector with Two-Phase Liquid Xenon

200 篇论文

The first underground data run of the ZEPLIN-II experiment has set a limit on the nuclear recoil rate in the two-phase xenon detector for direct dark matter searches. In this paper the results from this run are converted into the limits on…

天体物理学 · 物理学 2009-06-23 G. J. Alner et al.

In the present work we examine the possibility of detecting light dark matter particles (WIMP) utilizing their possible interactions with the electrons. Employing reasonable theoretical models we evaluate the expected event rates in the…

高能物理 - 唯象学 · 物理学 2019-04-11 J. D. Vergados

In this note the ILC's capabilities for detecting WIMPs and measuring their properties are studied. The expected signal cross section is derived in a model-independent way from the observed relic density of Dark Matter. Signal events are…

高能物理 - 实验 · 物理学 2009-02-02 C. Bartels , J. List

In this work we show that from the spectrum of particles of a 3-3-1 gauge model with heavy sterile neutrinos we can have up to three Cold Dark Matter candidates as WIMPs. We obtain their relic abundance and analyze their compatibility with…

高能物理 - 唯象学 · 物理学 2015-03-17 J. K. Mizukoshi , C. A. de S. Pires , F. S. Queiroz , P. S. Rodrigues da Silva

The status of the recent efforts in the direct search for Weak Interacting Massive Particle (WIMP) Dark Matter is briefly reviewed and the main achievements illustrated by the contributions presented to TAUP 99. The strategies followed in…

天体物理学 · 物理学 2009-10-31 Angel Morales

We report the final results of the Phase II SIMPLE measurements, comprising two run stages of 15 superheated droplet detectors each, the second stage including an improved neutron shielding. The analyses includes a refined signal analysis,…

Coherent elastic neutrino- and WIMP-nucleus interaction signatures are expected to be quite similar. This paper discusses how a next generation ton-scale dark matter detector could discover neutrino-nucleus coherent scattering, a…

高能物理 - 唯象学 · 物理学 2011-09-07 A. J. Anderson , J. M. Conrad , E. Figueroa-Feliciano , K. Scholberg , J. Spitz

The EDELWEISS-II experiment uses cryogenic heat-and-ionization detectors in order to detect the rare interactions from possible WIMP dark matter particles on Germanium nuclei. Recently, new-generation detectors with an interleaved electrode…

宇宙学与河外天体物理 · 物理学 2019-08-13 E. Armengaud

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of the scintillation timing…

We discuss the extent to which models of Weakly Interacting Massive Particle (WIMP) Dark Matter (DM) at and above the electroweak scale can be probed conclusively in future high energy and astroparticle physics experiments. We consider…

高能物理 - 唯象学 · 物理学 2019-02-14 Michael J. Baker , Andrea Thamm

DAMA is searching for rare processes by developing and using several kinds of radiopure scintillators: in particular, NaI(Tl), liquid Xenon and CaF$_2$(Eu). The main results are here summarized with particular attention to the investigation…

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with photomultiplier tubes submerged in the cryogen with nearly 4pi coverage of a 500 kg (150 kg) target (fiducial) mass. The high light…

仪器与探测器 · 物理学 2011-10-06 Andrew Hime

The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first…

The search for neutrinoless double beta decay and WIMP dark matter has a broad potential to test particle physics beyond the standard model. During the last years, the analysis of various contributions to the double beta decay rate by the…

高能物理 - 唯象学 · 物理学 2007-05-23 H. V. Klapdor-Kleingrothaus , H. Päs

SIMPLE (Superheated Instrument for Massive ParticLE searches) employs superheated droplet detectors (SDDs) to search for Weakly Interacting Massive Particle (WIMP) dark matter. As a result of the intrinsic SDD insensitivity to minimum…

天体物理学 · 物理学 2016-11-03 J. I. Collar , T. A. Girard , D. Limagne , H. S. Miley , T. Morlat , J. Puibasset , G. Waysand

We consider the prospects for the detection of relatively light dark matter through direct annihilation to neutrinos. We specifically focus on the detection possibilities of water Cherenkov and liquid scintillator neutrino detection…

高能物理 - 唯象学 · 物理学 2010-04-30 Jason Kumar , John G. Learned , Stefanie Smith

Thin and large area NaI(Tl) scintillator to search for WIMPs dark matter was developed. The performance of thin and wide area NaI(Tl) showed good enough to search for dark matter. The energy threshold was as low as 2keV and the energy…

仪器与探测器 · 物理学 2014-06-06 K. Harada , K. Fushimi , S. Nakayama , R. Orito , S. Iida , S. Ito , H. Ejiri , T. Shima , R. Hazama , E. Matsumoto , H. Ito , K. Imagawa