相关论文: Artifact Correction for Echo-Planar Imaging at Low…
Nyquist ghost artifacts in EPI are originated from phase mismatch between the even and odd echoes. However, conventional correction methods using reference scans often produce erroneous results especially in high-field MRI due to the…
Structured low-rank matrix models have previously been introduced to enable calibrationless MR image reconstruction from sub-Nyquist data, and such ideas have recently been extended to enable navigator-free echo-planar imaging (EPI) ghost…
Purpose: We propose and evaluate a new structured low-rank method for EPI ghost correction called Robust Autocalibrated LORAKS (RAC-LORAKS). The method can be used to suppress EPI ghosts arising from the differences between different…
PURPOSE: To correct line-to-line delays and phase errors in echo-planar imaging (EPI). THEORY AND METHODS: EPI- trajectory auto-corrected image reconstruction (EPI-TrACR) is an iterative maximum-likelihood technique that exploits data…
Purpose: This work aims to develop a robust Nyquist ghost correction method for multishot echo-planar imaging (EPI). The method helps correct challenging Nyquist ghosts, particularly on scanners with high-performance gradients or ultra-high…
Purpose: To develop a truly calibrationless reconstruction method that derives ESPIRiT maps from uniformly-undersampled multi-channel MR data by deep learning. Methods: ESPIRiT, one commonly used parallel imaging reconstruction technique,…
Echo Planar Imaging (EPI) is widely used for its rapid acquisition but suffers from severe geometric distortions due to B0 inhomogeneities, particularly along the phase encoding direction. Existing methods follow a two-step process:…
Objective. EEG data collected during fMRI acquisition are contaminated with MRI gradients and ballistocardiogram (BCG) artifacts, in addition to artifacts of physiological origin. There have been several attempts for reducing these…
Purpose: To develop new encoding and reconstruction techniques for fast multi-contrast quantitative imaging. Methods: The recently proposed Echo Planar Time-resolved Imaging (EPTI) technique can achieve fast distortion- and blurring-free…
We introduce wave encoded acquisition and reconstruction techniques for highly accelerated echo planar imaging (EPI) with reduced g-factor penalty and image artifacts. Wave-EPI involves playing sinusoidal gradients during the EPI readout…
We introduce a structured low rank algorithm for the calibration-free compensation of field inhomogeneity artifacts in Echo Planar Imaging (EPI) MRI data. We acquire the data using two EPI readouts that differ in echo-time (TE). Using time…
Objective: Analysis of the electroencephalogram (EEG) for epileptic spike and seizure detection or brain-computer interfaces can be severely hampered by the presence of artifacts. The aim of this study is to describe and evaluate a fast…
In recent studies on MRI reconstruction, advances have shown significant promise for further accelerating the MRI acquisition. Most state-of-the-art methods require a large amount of fully-sampled data to optimise reconstruction models,…
Purpose: To introduce a combined machine learning (ML) and physics-based image reconstruction framework that enables navigator-free, highly accelerated multishot echo planar imaging (msEPI), and demonstrate its application in…
MRI systems are traditionally engineered to produce close to idealized performance, enabling a simplified pulse sequence design philosophy. An example of this is control of eddy currents produced by gradient fields; usually these are…
Existing light field representations, such as epipolar plane image (EPI) and sub-aperture images, do not consider the structural characteristics across the views, so they usually require additional disparity and spatial structure cues for…
In this paper, a novel convolutional neural network (CNN)-based framework is developed for light field reconstruction from a sparse set of views. We indicate that the reconstruction can be efficiently modeled as angular restoration on an…
Transcranial ultrasound must overcome the significant challenge of the human skull, limiting both imaging and therapeutic applications. While high-fidelity numerical simulations can compensate for skull-induced distortions, they require…
Recent learning-based correction approaches in EPI estimate a displacement field, unwarp the reversed-PE image pair with the estimated field, and average the unwarped pair to yield a corrected image. Unsupervised learning in these…
Reducing the scanning time of very-low field (VLF) magnetic resonance imaging (MRI) scanners, commonly employed for stroke diagnosis, can enhance patient comfort and operational efficiency. The conventional parallel imaging (PI) technique…