相关论文: Sensitivity Evaluation of SU(1,1) Interferometers …
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is…
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, 'truncated SU(1,1)' interferometer Anderson et al. (Phys. Rev. A 95, 063843 (2017)) showed how to optimize the…
We theoretically study the phase sensitivity of the SU(1,1) interferometer with a coherent light together with a squeezed vacuum input case using the method of homodyne. We find that the homodyne detection has better sensitivity than the…
The sensitivity properties of an SU(1,1) interferometer made of two cascaded parametric amplifiers, as well as of an ordinary SU(2) interferometer preceded by a squeezer and followed by an anti-squeezer, are theoretically investigated.…
Absolute sensitivity is measured for the phase measurement in an SU(1,1) type interferometer and the results are compared to that of a Mach-Zehnder interferometer operated under the condition of the same intra-interferometer intensity. The…
We theoretically study the effects of loss on the phase sensitivity of an SU(1,1) interferometer with parity detection with various input states. We show that although the sensitivity of phase estimation decreases in the presence of loss,…
To improve the phase sensitivity, multi-photon subtraction schemes within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of…
Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the…
Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these…
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second…
We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input…
We consider an SU(1,1) interferometer employing four-wave mixers that is fed with two-mode states which are both coherent and intelligent states of the SU(1,1) Lie group. It is shown that the phase sensitivity of the interferometer can be…
An ${\rm SU(1,1)}$ interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field ${\rm SU(1,1)}$…
We theoretically investigate the phase sensitivity with parity detection on an SU(1,1) interferometer with a coherent state combined with a squeezed vacuum state. This interferometer is formed with two parametric amplifiers for beam…
We study the phase sensitivity in the conventional $SU(2)$ and nonconventional $SU(1,1)$ interferometers with the coherent and squeezed vacuum input state via the quantum Cramer-Rao bound. We explicitly construct the detection scheme that…
We perform a detailed analysis of how an amplified interferometer can be used to enhance the quality of a dispersive qubit measurement, such as one performed on a superconducting transmon qubit, using homodyne detection on an amplified…
Multimode quantum light has promising applications in many areas of physics, such as quantum communications and quantum computing. However, its multimode nature also makes it challenging to measure its properties. Recently [Optica Quantum…
By performing two local displacement operations (LDOs) inside an SU(1,1) interferometer, called as the displacement-assisted SU(1,1) [DSU(1,1)], both the phase sensitivity based on homodyne detection and quantum Fisher information (QFI)…
The SU(1,1) interferometer can be thought of as a Mach-Zehnder interferometer with its linear beamsplitters replaced with parametric nonlinear optical processes. We consider the cases of bright and vacuum-seeded SU(1,1) interferometers…
We study the phase sensitivity of SU(2) and SU(1,1) interferometers fed by two-mode field states which are intelligent states for Hermitian generators of the SU(2) and SU(1,1) groups, respectively. Intelligent states minimize uncertainty…