中文
相关论文

相关论文: EPC-3D-Diff: Equivariant Physics Consistent Condit…

200 篇论文

Electroencephalography (EEG) decoding requires models that can effectively extract and integrate complex temporal, spectral, and spatial features from multichannel signals. To address this challenge, we propose a lightweight and…

人机交互 · 计算机科学 2026-01-21 Haodong Zhang , Jiapeng Zhu , Yitong Chen , Hongqi Li

Magnetic Resonance (MR) imaging plays an essential role in contemporary clinical diagnostics. It is increasingly integrated into advanced therapeutic workflows, such as hybrid Positron Emission Tomography/Magnetic Resonance (PET/MR) imaging…

图像与视频处理 · 电气工程与系统科学 2025-07-17 Jiaxu Zheng , Meiman He , Xuhui Tang , Xiong Wang , Tuoyu Cao , Tianyi Zeng , Lichi Zhang , Chenyu You

Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy (IGRT) to provide updated patient anatomy information for cancer treatments. However, CBCT images often suffer from streaking artifacts and…

计算机视觉与模式识别 · 计算机科学 2023-11-02 Jiarui Zhu , Werxing Chen , Hongfei Sun , Shaohua Zhi , Jing Qin , Jing Cai , Ge Ren

How can diffusion models process 3D geometries in a coarse-to-fine manner, akin to our multiscale view of the world? In this paper, we address the question by focusing on a fundamental biochemical problem of generating 3D molecular…

机器学习 · 计算机科学 2024-10-29 Jiwoong Park , Yang Shen

Significant uncertainty in climate prediction and cloud physics is tied to observational gaps relating to shallow scattered clouds. Addressing these challenges requires remote sensing of their three-dimensional (3D) heterogeneous volumetric…

计算机视觉与模式识别 · 计算机科学 2024-03-12 Roi Ronen , Ilan Koren , Aviad Levis , Eshkol Eytan , Vadim Holodovsky , Yoav Y. Schechner

Computed tomography (CT) provides rich 3D anatomical details but is often constrained by high radiation exposure, substantial costs, and limited availability. While standard chest X-rays are cost-effective and widely accessible, they only…

计算机视觉与模式识别 · 计算机科学 2026-03-30 Martin Rath , Morteza Ghahremani , Yitong Li , Ashkan Taghipour , Marcus Makowski , Christian Wachinger

Existing methods for restoring degraded human-centric images often struggle with insufficient fidelity, particularly in human body restoration (HBR). Recent diffusion-based restoration methods commonly adapt pre-trained text-to-image…

计算机视觉与模式识别 · 计算机科学 2026-02-05 Jue Gong , Zihan Zhou , Jingkai Wang , Shu Li , Libo Liu , Jianliang Lan , Yulun Zhang

To obtain high-quality positron emission tomography (PET) scans while reducing radiation exposure to the human body, various approaches have been proposed to reconstruct standard-dose PET (SPET) images from low-dose PET (LPET) images. One…

图像与视频处理 · 电气工程与系统科学 2023-08-22 Zeyu Han , Yuhan Wang , Luping Zhou , Peng Wang , Binyu Yan , Jiliu Zhou , Yan Wang , Dinggang Shen

To shorten the door-to-puncture time for better treating patients with acute ischemic stroke, it is highly desired to obtain quantitative cerebral perfusion images using C-arm cone-beam computed tomography (CBCT) equipped in the…

图像与视频处理 · 电气工程与系统科学 2024-12-30 Haotian Zhao , Ruifeng Chen , Jing Yan , Juan Feng , Jun Xiang , Yang Chen , Dong Liang , Yinsheng Li

Equivariant diffusion models have achieved impressive performance in 3D molecule generation. These models incorporate Euclidean symmetries of 3D molecules by utilizing an SE(3)-equivariant denoising network. However, specialized equivariant…

机器学习 · 计算机科学 2025-07-01 Yuhui Ding , Thomas Hofmann

Current methods based on deep learning for self-supervised low-dose CT (LDCT) reconstruction, while reducing the dependence on paired data, face the problem of significantly decreased generalization when training with single-dose data and…

计算机视觉与模式识别 · 计算机科学 2026-01-22 Guoquan Wei , Liu Shi , Zekun Zhou , Mohan Li , Cunfeng Wei , Wenzhe Shan , Qiegen Liu

Extending the translation equivariance property of convolutional neural networks to larger symmetry groups has been shown to reduce sample complexity and enable more discriminative feature learning. Further, exploiting additional symmetries…

计算机视觉与模式识别 · 计算机科学 2025-02-12 Lisa Weijler , Pedro Hermosilla

Recent methods for molecular generation face a trade-off: they either enforce strict equivariance with costly architectures or relax it to gain scalability and flexibility. We propose a frame-based diffusion paradigm that achieves…

机器学习 · 计算机科学 2025-10-07 Mohan Guo , Cong Liu , Patrick Forré

Low-dose computed tomography (CT) has attracted a major attention in the medical imaging field, since CT-associated x-ray radiation carries health risks for patients. The reduction of CT radiation dose, however, compromises the…

计算机视觉与模式识别 · 计算机科学 2019-07-16 Hongming Shan , Yi Zhang , Qingsong Yang , Uwe Kruger , Mannudeep K. Kalra , Ling Sun , Wenxiang Cong , Ge Wang

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

医学物理 · 物理学 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…

医学物理 · 物理学 2022-05-24 Junbo Peng

Diffusion models learn strong image priors that can be leveraged to solve inverse problems like medical image reconstruction. However, for real-world applications such as 3D Computed Tomography (CT) imaging, directly training diffusion…

计算机视觉与模式识别 · 计算机科学 2025-12-23 Taewon Yang , Jason Hu , Jeffrey A. Fessler , Liyue Shen

In Europe the 20% of the CT scans cover the thoracic region. The acquired images contain information about the cardiovascular system that often remains latent due to the lack of contrast in the cardiac area. On the other hand, the contrast…

High anisotropy in volumetric medical images can lead to the inconsistent quantification of anatomical and pathological structures. Particularly in optical coherence tomography (OCT), slice spacing can substantially vary across and within…

图像与视频处理 · 电气工程与系统科学 2024-10-15 Coen de Vente , Mohammad Mohaiminul Islam , Philippe Valmaggia , Carel Hoyng , Adnan Tufail , Clara I. Sánchez

Synthetic PET images are valuable for quantitative imaging workflow development, scalable virtual imaging trials, and deep learning model training, but conventional physics-based simulation approaches are computationally intensive, limited…

计算机视觉与模式识别 · 计算机科学 2026-05-21 Suya Li , Kaushik Dutta , Debojyoti Pal , Jingqin Luo , Kooresh I. Shoghi