中文
相关论文

相关论文: PHASOR: Anatomy- and Phase-Consistent Volumetric D…

200 篇论文

Photon-Counting Computed Tomography (PCCT) is a novel imaging modality that simultaneously acquires volumetric data at multiple X-ray energy levels, generating separate volumes that capture energy-dependent attenuation properties.…

人机交互 · 计算机科学 2025-08-21 Mohit Sharma , Emma Nilsson , Martin Falk , Talha Bin Masood , Lee Jollans , Anders Persson , Tino Ebbers , Ingrid Hotz

Dynamic contrast enhanced computed tomography (CT) is an imaging technique that provides critical information on the relationship of vascular structure and dynamics in the context of underlying anatomy. A key challenge for image processing…

Contrast agents in dynamic contrast enhanced magnetic resonance imaging allow to localize tumors and observe their contrast kinetics, which is essential for cancer characterization and respective treatment decision-making. However, contrast…

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is essential for breast cancer diagnosis due to its ability to characterize tissue through contrast agent kinetics. However, traditional DCE-MRI protocols require multiple…

计算机视觉与模式识别 · 计算机科学 2025-01-28 Ruben D. Fonnegra , Maria Liliana Hernández , Juan C. Caicedo , Gloria M. Díaz

Improving the spatial resolution of CT images is a meaningful yet challenging task, often accompanied by the issue of noise amplification. This article introduces an innovative framework for noise-controlled CT super-resolution utilizing…

计算机视觉与模式识别 · 计算机科学 2025-02-17 Yuang Wang , Siyeop Yoon , Rui Hu , Baihui Yu , Duhgoon Lee , Rajiv Gupta , Li Zhang , Zhiqiang Chen , Dufan Wu

Molecularly targeted contrast enhanced ultrasound (mCEUS) is a clinically promising approach for early cancer detection through targeted imaging of VEGFR2 (KDR) receptors. We have developed computational enhancement techniques for mCEUS…

图像与视频处理 · 电气工程与系统科学 2020-06-23 Andrew A. Berlin , Mon Young , Ahmed El Kaffas , Sam Gambhir , Amelie Lutz , Maria Luigia Storto , Juergen Willmann

Accurate quantification in positron emission tomography (PET) is essential for accurate diagnostic results and effective treatment tracking. A major issue encountered in PET imaging is attenuation. Attenuation refers to the diminution of…

The vascular structure in retinal images plays a crucial role in ophthalmic diagnostics, and its accuracies are directly influenced by the quality of the retinal image. Contrast enhancement is one of the crucial steps in any segmentation…

计算机视觉与模式识别 · 计算机科学 2025-04-22 Adnan Shaout , Jiho Han

Latest methods for visual counterfactual explanations (VCE) harness the power of deep generative models to synthesize new examples of high-dimensional images of impressive quality. However, it is currently difficult to compare the…

计算机视觉与模式识别 · 计算机科学 2023-08-14 Philipp Vaeth , Alexander M. Fruehwald , Benjamin Paassen , Magda Gregorova

To obtain high-quality positron emission tomography (PET) scans while reducing radiation exposure to the human body, various approaches have been proposed to reconstruct standard-dose PET (SPET) images from low-dose PET (LPET) images. One…

图像与视频处理 · 电气工程与系统科学 2023-08-22 Zeyu Han , Yuhan Wang , Luping Zhou , Peng Wang , Binyu Yan , Jiliu Zhou , Yan Wang , Dinggang Shen

Multiphase contrast-enhanced computed tomography (CECT) scan is clinically significant to demonstrate the anatomy at different phases. In practice, such a multiphase CECT scan inherently takes longer time and deposits much more radiation…

图像与视频处理 · 电气工程与系统科学 2023-06-14 Rongjun Ge , Yuting He , Cong Xia , Yang Chen , Daoqiang Zhang , Ge Wang

The deployment of artificial intelligence in medical imaging is hindered by high computational complexity and resource-intensive processing of volumetric data. Although chest computed tomography (CT) volumes offer richer diagnostic…

计算机视觉与模式识别 · 计算机科学 2026-05-04 Shadid Yousuf , S. M. Mahbubur Rahman , Mohammed Imamul Hassan Bhuiyan

High anisotropy in volumetric medical images can lead to the inconsistent quantification of anatomical and pathological structures. Particularly in optical coherence tomography (OCT), slice spacing can substantially vary across and within…

图像与视频处理 · 电气工程与系统科学 2024-10-15 Coen de Vente , Mohammad Mohaiminul Islam , Philippe Valmaggia , Carel Hoyng , Adnan Tufail , Clara I. Sánchez

Abdominal CT data are limited by high annotation costs and privacy constraints, which hinder the development of robust segmentation and diagnostic models. We present a Prior-Integrated Variation Modeling (PIVM) framework, a diffusion-based…

计算机视觉与模式识别 · 计算机科学 2026-03-25 Dinglun He , Baoming Zhang , Xu Wang , Yao Hao , Deshan Yang , Ye Duan

Modality discrepancies have perpetually posed significant challenges within the realm of Automated Audio Captioning (AAC) and across all multi-modal domains. Facilitating models in comprehending text information plays a pivotal role in…

声音 · 计算机科学 2024-02-28 Liwen Tan , Yin Cao , Yi Zhou

Three-dimensional (3D) medical image enhancement, including denoising and super-resolution, is critical for clinical diagnosis in CT, PET, and MRI. Although diffusion models have shown remarkable success in 2D medical imaging, scaling them…

计算机视觉与模式识别 · 计算机科学 2026-04-21 Hongxu Jiang , Fei Li , Boxiao Yu , Ying Zhang , Kaleb Smith , Kuang Gong , Wei Shao

Diffusion models have emerged as potential tools to tackle the challenge of sparse-view CT reconstruction, displaying superior performance compared to conventional methods. Nevertheless, these prevailing diffusion models predominantly focus…

图像与视频处理 · 电气工程与系统科学 2023-09-06 Kai Xu , Shiyu Lu , Bin Huang , Weiwen Wu , Qiegen Liu

Positron Emission Tomography (PET) and Computed Tomography (CT) are essential for diagnosing, staging, and monitoring various diseases, particularly cancer. Despite their importance, the use of PET/CT systems is limited by the necessity for…

图像与视频处理 · 电气工程与系统科学 2024-10-30 Dac Thai Nguyen , Trung Thanh Nguyen , Huu Tien Nguyen , Thanh Trung Nguyen , Huy Hieu Pham , Thanh Hung Nguyen , Thao Nguyen Truong , Phi Le Nguyen

Image-generative artificial intelligence (AI) has garnered significant attention in recent years. In particular, the diffusion model, a core component of generative AI, produces high-quality images with rich diversity. In this study, we…

计算机视觉与模式识别 · 计算机科学 2024-09-13 Sho Ozaki , Shizuo Kaji , Toshikazu Imae , Kanabu Nawa , Hideomi Yamashita , Keiichi Nakagawa

Accurate correspondence matching in coronary angiography images is crucial for reconstructing 3D coronary artery structures, which is essential for precise diagnosis and treatment planning of coronary artery disease (CAD). Traditional…

计算机视觉与模式识别 · 计算机科学 2025-04-02 Lin Zhao , Xin Yu , Yikang Liu , Xiao Chen , Eric Z. Chen , Terrence Chen , Shanhui Sun