相关论文: Multi-Swing Transient Stability of Synchronous Gen…
Inverter-based resources (IBRs) are becoming increasingly prevalent in power systems. Due to the inherently low inertia of inverters, there is a heightened risk of disruptive voltage oscillations. A particular challenge in the operation of…
Under asymmetrical faults, analyzing the transient stability of grid-forming voltage-source converters (GFM-VSCs) becomes essential because their behavior fundamentally differs from that under symmetrical faults. When current limiting is…
Power electronic converters for integrating renewable energy resources into power systems can be divided into grid-forming and grid-following inverters. They possess certain similarities, but several important differences, which means that…
The virtual synchronous generator technology analogs the characteristics of the synchronous generator via the controller design. It improved the stability of the grid systems which include the new energy. At the same time, according to the…
High levels of penetration of distributed generation and aggressive reactive power compensation with modern power electronics may result in the reversal of active and reactive power flows in future distribution grids. The voltage stability…
The increasing penetration of renewable energy sources has been leading to the progressive phase-out of synchronous generators, which constitute the main source of frequency stability for electric power systems. In the light of these…
This paper presents a sub-switching period current-limiting control for a grid-tied inverter to prevent transient overcurrents during grid faults and enable seamless fault ride-through (FRT). Sudden grid-voltage disturbances, such as…
Synchronization instability of grid-tied converters during grid faults is a serious concern. For phase-locked loop (PLL) synchronized converters, synchronization stability during grid faults requires that PLL can resynchronize with the…
Grid-following (GFL) inverters have very different large-signal stability characteristics to synchronous generators, and convenient concepts such as the equal-area criterion and global energy function do not apply in the same way. Existing…
Ever-growing electrical loads are having a huge impact on the operation and stability of the power system. Moreover, the integration of renewable generation poses various challenges to the future power system, especially, regarding…
Transients of a grid-synchronized voltage source converter (VSC) are closely related to over- currents and voltages occurred under large disturbances (e.g. a grid fault). Previous analysis in evaluating these transients usually neglect the…
This paper shows that a necessary and sufficient condition for the small-signal stability of an inverter-integrated power system can be expressed in terms of semidefinite matrix inequalities determined only by the synchronous reactance of…
Rotational inertia is stabilizing the frequency of electric power systems against small and large disturbances, but it is also the cause for oscillations between generators. As more and more conventional generators are replaced by renewable…
Conventional power system optimization framework is becoming less reliable and efficient due to the stability issues brought by the ever-increasing inverter-interfaced renewable penetration. To ensure system stability during system…
The energy gradient theory is used to study the instability of Taylor-Couette flow between concentric rotating cylinders. This theory has been proposed in our previous works. In our previous studies, the energy gradient theory was…
In modern power systems, the operating point, at which the demand and supply are balanced, may take different values due to changes in loads and renewable generation levels. Understanding the dynamics of stressed power systems with a range…
The grid-following and grid-forming controls in voltage-source converters are considered as different operation modes and the synchronization mechanism of them are studied separately. In this article, the intrinsic relationships between…
Flow instability and turbulent transition can be well explained using a new proposed theory--Energy gradient theory [1]. In this theory, the stability of a flow depends on the relative magnitude of energy gradient in streamwise direction…
A case study on modeling adequacy of a grid in presence of renewable resources based on grid-forming converters (GFCs) is the subject matter of this paper. For this purpose, a 4-machine 11-bus IEEE benchmark model is modified by considering…
The stable operation of the electric power grid relies on a precisely synchronized state of all generators and machines. All machines rotate at exactly the same frequency with fixed phase differences, leading to steady power flows…