中文
相关论文

相关论文: Direct comparison of multi-ion optical clocks base…

200 篇论文

Optical frequency comparison of the 40Ca+ clock transition \nu_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition \nu_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio \nu_{Ca} / \nu_{Sr} = 0.957 631 202 358…

We report on an evaluation of an optical clock that uses the $\phantom{}^2S_{1/2} \rightarrow \phantom{}^2D_{5/2}$ transition of a single $^{88}$Sr$^+$ ion as the reference. In contrast to previous work, we estimate the effective…

Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below $1\times10^{-18}$. Scaling these systems to multiple, simultaneously…

Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of…

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an…

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Syst\'eme International) second that refers to Cs microwave clocks with fractional…

原子物理 · 物理学 2014-05-19 Ichiro Ushijima , Masao Takamoto , Manoj Das , Takuya Ohkubo , Hidetoshi Katori

The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the…

It is shown that the dynamic differential scalar polarisability of the $S_{1/2}-D_{5/2}$ transition in $^{138}$Ba$^+$ can be determined to an inaccuracy below $0.5\%$ across a wide wavelength range ($\lambda>700\,\mathrm{nm}$). This can be…

原子物理 · 物理学 2019-10-30 M. D. Barrett , K. J. Arnold , M. S. Safronova

We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved…

原子物理 · 物理学 2012-01-17 A. Yamaguchi , N. Shiga , S. Nagano , Y. Li , H. Ishijima , H. Hachisu , M. Kumagai , T. Ido

We have constructed an optical clock with a fractional frequency inaccuracy of 8.6e-18, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser-cool the Al+ ion and detect its…

量子物理 · 物理学 2013-05-29 C. -W. Chou , D. B. Hume , J. C. J. Koelemeij , D. J. Wineland , T. Rosenband

We report the first operation of a Ra$^{+}$ optical clock, a promising high-performance clock candidate. The clock uses a single trapped $^{226}$Ra$^{+}$ ion and operates on the $7s\ ^2S_{1/2}\rightarrow$ $6d\ ^2D_{5/2}$ electric quadrupole…

原子物理 · 物理学 2022-01-27 C. A. Holliman , M. Fan , A. Contractor , S. M. Brewer , A. M. Jayich

We report on a precision measurement of the differential static scalar polarizability $\Delta\alpha_0$ of the ${}^{2}\!S_{1/2} \rightarrow {}^{2}\!D_{5/2}$ optical clock transition in the $^{88}$Sr$^{+}$ ion. The polarizability was…

原子物理 · 物理学 2025-07-04 T. Lindvall , K. J. Hanhijärvi , T. Fordell , A. E. Wallin

We report a single-ion optical atomic clock with fractional frequency uncertainty of $5.5\times10^{-19}$ and fractional frequency stability of $3.5 \times10^{-16}/\sqrt{\tau/\mathrm{s}}$, based on quantum logic spectroscopy of a single…

We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical…

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been…

We report on a $^{88}$Sr$^{+}$ single-ion optical clock with an estimated fractional systematic uncertainty of $7.9\times 10^{-19}$. The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation…

原子物理 · 物理学 2025-10-02 T. Lindvall , T. Fordell , K. J. Hanhijärvi , M. Doležal , J. Rahm , S. Weyers , A. E. Wallin

We report a comprehensive evaluation of all known sources of systematic uncertainty for two independent $^{176}$Lu$^+$ single-ion optical references, finding total systematic uncertainty of $1.1\times10^{-19}$ and $1.4\times10^{-19}$ for…

原子物理 · 物理学 2025-12-09 K. J. Arnold , M. D. K. Lee , Zhao Qi , Qichen Qin , Zhang Zhao , N. Jayjong , M. D. Barrett

Improvements in atom-light coherence are foundational to progress in quantum information science, quantum optics, and precision metrology. Optical atomic clocks require local oscillators with exceptional optical coherence due to the…

We demonstrate a precision frequency measurement using a phase-stabilized 120-km optical fiber link over a physical distance of 50 km. The transition frequency of the 87Sr optical lattice clock at the University of Tokyo is measured to be…

Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter…

‹ 上一页 1 2 3 10 下一页 ›