相关论文: Discovery and rectification of an error in high re…
Uncertainty quantification is essential for scientific analysis, as it allows for the evaluation and interpretation of variability and reliability in complex systems and datasets. In their original form, multivariate statistical regression…
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in…
Laser power metrology at the National Institute of Standards and Technology (NIST) ranges 20 orders of magnitude from photon-counting (1000 photons/s) to 100 kW (10^23 photons/s at a wavelength of 1070 nm). As a part of routine practices,…
We present an extension to the robust phase estimation protocol, which can identify incorrect results that would otherwise lie outside the expected statistical range. Robust phase estimation is increasingly a method of choice for…
The Reactions with Relativistic Radioactive Beams (R$^3$B) collaboration of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, has constructed an experimental setup to perform fundamental studies of nuclear matter,…
It is challenging to achieve high precision energy resolution for large liquid scintillator detectors. Energy non-uniformity is one of the main obstacles. To surmount it, a calibration-data driven method was developed previously to…
At National Institute of Metrological Research (INRIM), an automated setup to calibrate DC Voltage generators, mainly top-level calibrators from 1 mV to 1 kV has been developed. The heart of the setup is an INRIM-built automated fixed…
After almost five decades of study of parity violation in hadronic systems, the determination of the seven weak meson-nucleon couplings is still incomplete. Whereas parity violation in nuclear systems is complicated by the intricacies of…
We consider the nu_mu to nu_e oscillation measurements that would be possible at upgraded 1 GeV and multi-GeV conventional neutrino sources driven by future megawatt-scale proton drivers. If these neutrino superbeams are used together with…
Modern commercial direct-current current transformers (DCCT) can measure currents up to the kA range with accuracies better than 1E-5. We discuss here a DCCT calibration method and its implementation with commercial instruments typically…
An accurate and extensive Inter-laboratory comparison between the laboratory for the calibration of multifunction electrical instruments of the National Institute of Metrology Research (INRIM) and a secondary high level electrical…
The accurate predictions and principled uncertainty measures provided by GP regression incur O(n^3) cost which is prohibitive for modern-day large-scale applications. This has motivated extensive work on computationally efficient…
Using $\Delta\chi^2$ which is defined by the difference of the number of events with the CP phase $\delta$ and the hypothetical one with $\delta=0$, we discuss correlations of errors of the CP phase and other oscillation parameters as well…
We present Very Long Baseline Array phase-referenced measurements of the parallax and proper motion of two pulsars, B0919+06 and B1857-26. Sub-milliarcsecond positional accuracy was obtained by simultaneously observing a weak calibrator…
This research leverages Conformal Prediction (CP) in the form of Conformal Predictive Systems (CPS) to accurately estimate uncertainty in a suite of machine learning (ML)-based radio metric models [1] as well as in a 2-D map-based ML path…
Accurately gauging the confidence level of Large Language Models' (LLMs) predictions is pivotal for their reliable application. However, LLMs are often uncalibrated inherently and elude conventional calibration techniques due to their…
This PhD thesis deals with the current experimental hint for large CP violation in the leptonic sector. We first quantify its global statistical significance, by combining the results from relevant neutrino oscillation experiments. As the…
Recent advancements in large language models (LLMs) have demonstrated remarkable reasoning capabilities. However, single-shot inference often yields unreliable results for complex reasoning tasks, leading researchers to explore multiple…
The stability and non-linearity of a commercial AH 2700A capacitance bridge were studied beyond its specified capabilities using the Thompson-Lampard Calculable Capacitor (TLCC) at LNE. The TLCC allows for continuous variation of measured…
In neutrino oscillation with non-standard interactions (NSI) the system is enriched with CP violation caused by phases due to NSI in addition to the standard lepton Kobayashi-Maskawa phase \delta. In this paper we show that it is possible…