中文
相关论文

相关论文: Calibration Plan for the SBC 10-kg Liquid Argon De…

200 篇论文

This work is part of an ongoing project to develop a Superheated Superconducting Granule (SSG) detector for cold dark matter and neutrinos. The response of SSG devices to nuclear recoils has been explored irradiating SSG detectors with a…

Neutrino cross sections are a critical ingredient in experiments that depend on neutrino scattering to reconstruct event kinematics and infer neutrino characteristics, like NOvA and T2K. An opportunity exists to reduce the 5-10% broad…

Experiments searching for weak interacting massive particles with noble gases such as liquid argon require very low detection thresholds for nuclear recoils. A determination of the scintillation efficiency is crucial to quantify the…

仪器与探测器 · 物理学 2015-09-02 W. Creus , Y. Allkofer , C. Amsler , A. D. Ferella , J. Rochet , L. Scotto-Lavina , M. Walter

The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises…

仪器与探测器 · 物理学 2025-09-23 J. Aalbers , D. S. Akerib , A. K. Al Musalhi , F. Alder , C. S. Amarasinghe , A. Ames , T. J. Anderson , N. Angelides , H. M. Araújo , J. E. Armstrong , M. Arthurs , A. Baker , S. Balashov , J. Bang , J. W. Bargemann , E. E. Barillier , K. Beattie , T. Benson , A. Bhatti , T. P. Biesiadzinski , H. J. Birch , E. Bishop , G. M. Blockinger , B. Boxer , C. A. J. Brew , P. Brás , S. Burdin , M. C. Carmona-Benitez , M. Carter , A. Chawla , H. Chen , Y. T. Chin , N. I. Chott , N. I. Chott , M. V. Converse , S. Contreras , R. Coronel , A. Cottle , G. Cox , D. Curran , C. E. Dahl , I. Darlington , S. Dave , A. David , J. Delgaudio , S. Dey , L. de Viveiros , L. Di Felice , C. Ding , J. E. Y. Dobson , E. Druszkiewicz , S. Dubey , C. L. Dunbar , S. R. Eriksen , A. Fan , N. M. Fearon , N. Fieldhouse , S. Fiorucci , H. Flaecher , E. D. Fraser , T. M. A. Fruth , R. J. Gaitskell , A. Geffre , J. Genovesi , C. Ghag , A. Ghosh , R. Gibbons , S. Gokhale , J. Green , M. G. D. van der Grinten , J. J. Haiston , C. R. Hall , T. Hall , S. Han , E. Hartigan-O'Connor , S. J. Haselschwardt , M. A. Hernandez , S. A. Hertel , G. J. Homenides , M. Horn , D. Q. Huang , D. Hunt , E. Jacquet , R. S. James , M. K. K , A. C. Kaboth , A. C. Kamaha , D. Khaitan , A. Khazov , J. Kim , Y. D. Kim , J. Kingston , R. Kirk , D. Kodroff , E. V. Korolkova , H. Kraus , S. Kravitz , L. Kreczko , V. A. Kudryavtsev , C. Lawes , D. S. Leonard , K. T. Lesko , C. Levy , J. Lin , A. Lindote , W. H. Lippincott , J. Long , M. I. Lopes , W. Lorenzon , C. Lu , S. Luitz , P. A. Majewski , A. Manalaysay , R. L. Mannino , C. Maupin , M. E. McCarthy , G. McDowell , D. N. McKinsey , J. McLaughlin , J. B. Mclaughlin , R. McMonigle , B. Mitra , E. Mizrachi , M. E. Monzani , E. Morrison , B. J. Mount , M. Murdy , A. St. J. Murphy , H. N. Nelson , F. Neves , A. Nguyen , C. L. O'Brien , I. Olcina , K. C. Oliver-Mallory , J. Orpwood , K. Y Oyulmaz , K. J. Palladino , J. Palmer , N. J. Pannifer , N. Parveen , S. J. Patton , B. Penning , G. Pereira , E. Perry , T. Pershing , A. Piepke , Y. Qie , J. Reichenbacher , C. A. Rhyne , G. R. C. Rischbieter , E. Ritchey , H. S. Riyat , R. Rosero , T. Rushton , D. Rynders , D. Santone , A. B. M. R. Sazzad , R. W. Schnee , G. Sehr , B. Shafer , S. Shaw , K. Shi , T. Shutt , J. J. Silk , C. Silva , G. Sinev , J. Siniscalco , A. M. Slivar , R. Smith , V. N. Solovov , P. Sorensen , J. Soria , I. Stancu , A. Stevens , T. J. Sumner , A. Swain , M. Szydagis , D. R. Tiedt , M. Timalsina , Z. Tong , D. R. Tovey , J. Tranter , M. Trask , M. Tripathi , K. Trengrove , A. Usón , A. C. Vaitkus , O. Valentino , V. Velan , A. Wang , J. J. Wang , Y. Wang , L. Weeldreyer , T. J. Whitis , K. Wild , M. Williams , W. J. Wisniewski , L. Wolf , F. L. H. Wolfs , S. Woodford , D. Woodward , C. J. Wright , Q. Xia , J. Xu , Y. Xu , M. Yeh , D. Yeum , W. Zha , H. Zhang , T. Zhang

Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…

天体物理仪器与方法 · 物理学 2011-01-27 Peter Sorensen

Discrimination between electron and nuclear recoil events in a liquid argon scintillation detector has been demonstrated with simulations by using the differences in the scintillation photon time distribution between these classes of…

天体物理学 · 物理学 2007-05-23 M. G. Boulay , A. Hime

The COHERENT collaboration is deploying a suite of low-energy detectors in a low-background corridor of the ORNL Spallation Neutron Source (SNS) to measure coherent elastic neutrino-nucleus scattering (CEvNS) on an array of nuclear targets…

仪器与探测器 · 物理学 2018-07-01 R. Tayloe

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…

仪器与探测器 · 物理学 2022-10-20 C. S. Amarasinghe , R. Coronel , D. Q. Huang , Y. Liu , M. Arthurs , S. Steinfeld , R. Gaitskell , W. Lorenzon

Organic liquid scintillators are used in a wide variety of applications in experimental nuclear and particle physics. Boron-loaded scintillators are particularly useful for detecting neutron captures, due to the high thermal neutron capture…

Large (up to $\sim 100$ kt) liquid argon time-projection chamber detectors are presently being considered for proton decay searches and neutrino astrophysics, as well as for far detectors for the next generation of long-baseline neutrino…

仪器与探测器 · 物理学 2015-06-16 Alberto Marchionni

Cloud and bubble chambers have historically been used for particle detection, capitalizing on supersaturation and superheating, respectively. Here we present new results from a prototype snowball chamber, in which an incoming particle…

高能物理 - 实验 · 物理学 2024-02-12 M. Szydagis , C. Levy , A. E. Bolotnikov , M. V. Diwan , G. J. Homenides , A. C. Kamaha , J. Martin , R. Rosero , M. Yeh

The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nucleus, producing nuclear recoils. These events will be discerned by their light to…

仪器与探测器 · 物理学 2010-03-26 Christian Regenfus

The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear…

The Liquid Argon Time Projection Chamber offers an innovative technology for a new class of massive detectors for rare-event detection. It is a precise tracking device that allows three-dimensional spatial reconstruction with mm-scale…

仪器与探测器 · 物理学 2015-06-15 A. Rubbia

A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams…

We have exposed a dual-phase Liquid Argon Time Projection Chamber (LAr-TPC) to a low energy pulsed narrowband neutron beam, produced at the Notre Dame Institute for Structure and Nuclear Astrophysics to study the scintillation light yield…

A technique using layered wavelength shifting, scintillating and non-scintillating films is presented to achieve discrimination of surface $\alpha$ events from low-energy nuclear recoils in liquid argon detectors. A discrimination power…

仪器与探测器 · 物理学 2020-07-08 M. G. Boulay , M. Kuźniak

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…

仪器与探测器 · 物理学 2020-11-25 M. Kimura , K. Aoyama , M. Tanaka , K. Yorita

According to many dark matter models, a potential signal registered in a detector would feature a single-scattering nuclear recoil (NR). So, it is crucial to calibrate the detector's response to NR events. The conventional calibrations…