相关论文: Technical assessment of a novel vertical CT system…

200 篇论文

Purpose: To evaluate reliability of upright CT for proton dose calculation and feasibility of a simplified phantom configuration for accelerated routine QA. Methods: A calibration phantom was scanned on an upright CT following consensus…

Verification of patient specific proton stopping powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to…

Objective: To propose a CBCT dose optimization method using readily available measurement equipment in radiation oncology departments. Approach: A 0.6cc air kerma (Kair) calibrated Farmer chamber measured Kair at isocenter for five default…

医学物理 · 物理学 2025-02-04 S. Gros , J. Bian , J. Jackson , M. Delafuente , H. Kang , W. Small , M. Mahesh

Treatment planning systems at proton-therapy centres generally use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body,…

Recently, X-ray imaging dose from computed tomography (CT) or cone beam CT (CBCT) scans has become a serious concern. Patient-specific imaging dose calculation has been proposed for the purpose of dose management. While Monte Carlo (MC)…

医学物理 · 物理学 2015-05-30 Xun Jia , Hao Yan , Xuejun Gu , Steve B. Jiang

Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…

Computed Tomography (CT) measures the attenuation coefficient of an object and converts the value assigned to each voxel into a CT number. In radiation therapy, CT number, which is directly proportional to the linear attenuation…

医学物理 · 物理学 2015-03-13 Dong Joo Rhee , Sung-woo Kim , Young Min Moon , Jung Ki Kim , Dong Hyeok Jeong

A renewed interest in upright therapy is currently driven by the availability of upright positioning and imaging systems. Aside from reduced cost, upright positioning possibly provides clinical advantages. The comparison between upright and…

医学物理 · 物理学 2024-06-18 M. C. Martire , L. Volz , C. Galeone , M. Durante , M. Pankuch , C. Graeff

We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of…

While compressed sensing (CS) based reconstructions have been developed for low-dose CBCT, a clear understanding on the relationship between the image quality and imaging dose at low dose levels is needed. In this paper, we qualitatively…

医学物理 · 物理学 2015-06-03 Hao Yan , Laura Cervino , Xun Jia , Steve B. Jiang

Radiation dose is an important performance indicator of a dedicated breast CT (DBCT). In this paper, the method of putting thermoluminescent dosimeters (TLD) into a breast shaped PMMA phantom to study the dose distribution in breasts was…

医学物理 · 物理学 2013-05-14 Shen Shan-Wei , Wang Yan-Fang , Shu Hang , Tang Xiao , Wei Cun-Feng , Song Yu-Shou , Shi Rong-Jian , Wei Long

How to evaluate and compare image quality from different sub-micrometer (sub$\mu$) CT scans? A simple test phantom made of polymer microbeads is used for recording projection images as well as 13 CT scans in a number of commercial and…

The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was…

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens,…

Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better…

Background: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has…

The use of CT imaging is important for screening, diagnosis, therapy planning, and prognosis of lung cancers. Unfortunately, due to differences in imaging protocols and scanner models, CT images acquired by different means may show large…

计算机视觉与模式识别 · 计算机科学 2026-05-05 Md Shifatul Ahsan Apurba , Md Selim , Jin Chen

Purpose: To apply a convolutional neural network (CNN) to develop a system that segments intensity calibration phantom regions in computed tomography (CT) images, and to test the system in a large cohort to evaluate its robustness. Methods:…

计算机视觉与模式识别 · 计算机科学 2020-12-22 Keisuke Uemura , Yoshito Otake , Masaki Takao , Mazen Soufi , Akihiro Kawasaki , Nobuhiko Sugano , Yoshinobu Sato

In this work, image analysis techniques used in astrophysics to detect low-contrast signals have been adapted in the processing of Computed Tomography (CT) images, combining Centroidal Voronoi Tessellation (CVT) and machine learning…

医学物理 · 物理学 2025-03-11 Lorenzo Lasagni

Background: Upright proton therapy with compact delivery systems has the potential to reduce costs for treatments but could also lead to broadening of the beam penumbra due to energy selection close to the patient. Purpose: This study aims…

医学物理 · 物理学 2025-08-22 Erik Engwall , Victor Mikhalev , Johan Sundström , Otte Marthin , Viktor Wase