相关论文: Improved PLL Design for Transient Stability Enhanc…
Differing from synchronous generators, there are lack of physical laws governing the synchronization dynamics of voltage-source converters (VSCs). The widely used phase-locked loop (PLL) plays a critical role in maintaining the synchronism…
Grid-synchronization stability (GSS) is an emerging stability issue of grid-tied voltage source converters (VSCs), which can be provoked by severe grid voltage sags. Although a qualitative understanding of the mechanism behind the loss of…
With the increased penetration of renewable energy and reduced proportion of synchronous generators, the low-inertia characteristics of todays power system become prominent, and the transient stability issue of grid following converter…
Synchronization instability of grid-tied converters during grid faults is a serious concern. For phase-locked loop (PLL) synchronized converters, synchronization stability during grid faults requires that PLL can resynchronize with the…
Deploying synchronous condensers (SynCons) near grid-following renewable energy sources (GFLRs) is an effective and increasingly adopted strategy for grid support. However, the potential transient instability risks in such configurations…
The modern power grid features the high penetration of power converters, which widely employ a phase-locked loop (PLL) for grid synchronization. However, it has been pointed out that PLL can give rise to small-signal instabilities under…
In current generation digital phase locked loop (DPLL) architectures, techniques like adaptive loop bandwidth with loop order switching and switched phase-detection are employed to achieve better lock time and jitter performance. This work…
Grid-following (GFL) inverters are commonly used for integrating renewable energy sources into power grids. However, the dynamic performance of GFL models can be significantly impacted by the Phase-Locked Loop (PLL) in a weak grid, leading…
Integrating grid-forming converters (GFMCs) into grid-following converter (GFLC)-dominated power systems enhances the grid strength, but GFMCs' current-limiting characteristic triggers dynamic switching between constant voltage control…
The grid-following and grid-forming controls in voltage-source converters are considered as different operation modes and the synchronization mechanism of them are studied separately. In this article, the intrinsic relationships between…
Small-signal instability of grid-connected power converters may arise when the converters use a phase-locked loop (PLL) to synchronize with a weak grid. Commonly, this stability problem (referred as PLL-synchronization stability in this…
This paper presents an extensive framework focused on the control design, along with stability and performance analysis, of Grid-Following Inverters (GFL). It aims to ensure their effective operation under both stiff and weak grid…
This paper presents a novel strategy for the synchronization of grid-following Voltage Source Converters (VSCs) in power systems with low rotational inertia. The proposed synchronization unit is based on emulating the physical properties of…
In scenarios where synchronous generators (SGs) and grid-following renewable energy sources (GFLR) are co-located, existing research, which mainly focuses on the first-swing stability of SGs, often overlooks ongoing dynamic interactions…
We consider a grid-connected voltage source converter (VSC) and address the problem of estimating the grid angle and frequency, information that is essential for an appropriate operation of the converter. We design phase-locked loop (PLL)…
Synchronous reference frame phase-looked loop (SRF-PLL) techniques are widely used for interfacing and control applications in the power systems and energy conversion at large. Since a PLL system synchronizes its output with an exogenous…
Low-frequency oscillations (LFOs) present a significant challenge to the stability and reliability of power systems, especially in grids with a high penetration of renewable energy sources. Traditional grid-following (GFL) inverters have…
The phase-locked loop (PLL) used in the doubly fed induction generator (DFIG) can cause frequency coupling phenomena, which will give negative resistance characteristics ofthe DFIG at low frequency, resulting in stability issues under weak…
Grid-following inverters have been widely adopted as a grid interface for renewable energy, and ensuring their small-signal and large-signal stability is critical to modern power systems. Their large-signal, or transient, stability is a…
High penetration of distributed generators (DG) in modern power grids creates angle, voltage, and frequency instabilities. Most of the work in the literature has focused on small-signal stability analysis of single grid-connected inverters…