相关论文: Spectrum of five-times ionized krypton: Kr VI
The origin of the identical gamma-ray energies (IB) observed in the K=33/2$^+$ and K=16$^+$ bands in $^{177}$Lu and $^{178}$Hf respectively is investigated using deformed Hartree-Fock and Angular Momentum Projection technique. We find that…
We improve by a factor of 4-20 the energy accuracy of the strongest soft X-ray transitions of Fe XVII ions by resonantly exciting them in an electron beam ion trap with a monochromatic beam at the P04 beamline of the PETRA III synchrotron…
The paper presents the results of multi-wave radio observations of sixteen red dwarfs with Earth-like planets in the habitable zones on RATAN-600. In the passage mode, radiometers of four frequency ranges of 22, 11, 4.7 and 2.3 GHz (1.38,…
Single photoionization cross sections for Kr-like Rb$^+$ ions are reported in the energy (wavelength) range 22 eV (564 \AA) to 46 eV (270 \AA). Theoretical cross section calculations for this {\it trans}-Fe element are compared with…
We present basic observational data on the 6C** sample. This is a new sample of radio sources drawn from the 151 MHz 6C survey, which was filtered with radio criteria chosen to optimize the chances of finding radio galaxies at z > 4. The…
Neutron-deficient krypton isotopes are of particular interest due to the coexistence of oblate and prolate shapes in low-lying states and the transition of ground-state from one dominate shape to another as a function of neutron number. A…
Rotationally-resolved Fourier-transform spectra of laser-induced fluorescence (LIF) $A^1\Sigma^+_u\sim b^3\Pi_u \rightarrow X^1\Sigma^+_g$ of K$_2$ molecules were recorded and analyzed yielding 4053 term values of spin-orbit (SO) coupled $A…
With the intention of creating a complete simulation of the Thick GEM detector, this work presents a partial simulation of the interaction of 6 keV X-Ray radiation with a gas volume. For the gas, it was used pure Argon, Xenon and CO2 as…
The reflectivity of single-crystalline CoO has been studied by optical spectroscopy for wave numbers ranging from 100 to 28,000\wn and for temperatures 8 $< T <$ 325 K\@. A splitting of the cubic IR-active phonon mode on passing the…
We present the first INTEGRAL observations of the type 1.5 Seyfert galaxy NGC 4151. Combining several INTEGRAL observations performed during 2003, totaling about 400 ks of exposure time, allows us to study the spectrum in the 2 - 300 keV…
We report the measurement of infrared transmission of large C60 single crystals. The spectra exhibit a very rich structure with over 180 vibrational absorptions visible in the 100 - 4000 cm-1 range. Many silent modes are observed to have…
The NGC 2024 FIR 5/6 region was observed in the 6.9 mm continuum with an angular resolution of about 1.5 arcsec. The 6.9 mm continuum map shows four compact sources, FIR 5w, 5e, 6c, and 6n, as well as an extended structure of the ionization…
The National Ignition Facility at Lawrence Livermore National Laboratory uses $^{86}$Kr as a diagnostic tool to measure the neutron flux produced by fusion reactions. As krypton is chemically inert, it can be implanted directly into the…
Reliable tungsten spectroscopy is essential for modelling and diagnosing tungsten-containing plasmas, particularly in edge/divertor conditions where neutral tungsten (WI) is produced by sputtering and contributes to visible/near-UV…
We present a complete library of synthetic spectra based on Kurucz's codes that covers the 2500-10500 Ang wavelength range at resolving powers 20,000, 11,500 (GAIA), 8500 (RAVE), 2000 (SLOAN) and uniform dispersions of 1 and 10 Ang/pix. The…
High precision spectroscopy of the low-lying dielectronic resonances in fluorine-like nickel ions were determined by employing the merged electron-ion beam at the heavy-ion storage ring CSRm. The measured dielectronic resonances are…
The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed…
We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an…
The work to be described falls into three parts: (1) The computer-controlled CW spectrometer was designed to supplement the Manchester pulsed microwave spectrometer in situations where rapid nuclear relaxation makes spin-echo spectroscopy…
We use optical-optical double-resonance (OODR) spectroscopy with a continuous wave (CW) pump and a cavity-enhanced frequency comb probe to measure high rotational energy levels of methane in the upper part of the triacontad polyad (P6). A…