相关论文: A Grid-Forming HVDC Series Tapping Converter Using…
Transients of a grid-synchronized voltage source converter (VSC) are closely related to over- currents and voltages occurred under large disturbances (e.g. a grid fault). Previous analysis in evaluating these transients usually neglect the…
With the emergence of low-inertia microgrids powered by inverter-based generation, there remains a concern about the operational resilience of these systems. Grid-forming inverters (GFMs), enabled by various device-level (primary) and…
The modern power grid features the high penetration of power converters, which widely employ a phase-locked loop (PLL) for grid synchronization. However, it has been pointed out that PLL can give rise to small-signal instabilities under…
Under asymmetrical faults, analyzing the transient stability of grid-forming voltage-source converters (GFM-VSCs) becomes essential because their behavior fundamentally differs from that under symmetrical faults. When current limiting is…
Modular multilevel converter (MMC) has complex topology, control architecture and broadband harmonic spectrum. For this, linear-time-periodic (LTP) theory, covering multi-harmonic coupling relations, has been adopted for MMC impedance…
There is a trade-off between transient performance and line current distortion of the DC bus voltage control of single-phase grid-connected voltage source converters. This paper presents an improved DC bus voltage control scheme of such…
The effective way of energy transmission plays a key factor in improving the overall transmission systems efficiency. Many methods are proposed to control the reactive power flow, voltage fluctuations and power factor improvement, The…
Due to generation retirements and growth of renewable energy sources integration, there will be widespread changes in the real and reactive power flow in nowadays power systems. These changes also bring about challenges on system operation…
As the last resort of emergency control, controlled islanding is an effective means of preventing fault-propagation and a system-wide blackout. However, conventional AC transmission lines are unavailable to be employed for power exchange…
Voltage regulation under conventional grid-forming controllers is tightly coupled to power sharing and dc-link dynamics. Consequently, its tracking accuracy deteriorates during grid faults, sudden power sharing changes, or dc-bus voltage…
Grid forming control applied to power converters that interface storage or renewable generation to the power grid, has been identified as a potential solution to facilitate a substantial share of converter-based renewable generation in the…
An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage…
A family of interleaved current-fed high step-up dc-dc converters are introduced and analyzed here by combining a voltage multiplier (VM) and an active clamp circuit for high-voltage high-power applications. Low input currents and output…
Fault detection and reconfiguration in fault-tolerant converters may complicated and necessitate using all-purpose microprocessors and high-speed sensors to guarantee the satisfactory performance of power converters. Therefore, providing…
In modern power systems, grid-forming power converters (GFMCs) have emerged as an enabling technology. However, the modeling of single-phase GFMCs faces new challenges. In particular, the nonlinear orthogonal signal generation unit, crucial…
PUBLISHED ON IEEE/ASME TRANSACTIONS ON MECHATRONICS, DOI: 10.1109/TMECH.2021.3100150. Ideally, accurate sensor measurements are needed to achieve a good performance in the closed-loop control of mechatronic systems. As a consequence, sensor…
Partial resonance high frequency AC link converters are recognized to provide soft-switching, single-stage power conversion. They are highly reliable due to elimination of DC capacitors. Previous work has focused on proof of concept…
This article introduces two control frameworks: one for Grid-Following (GFL) inverters aiding Grid-Forming (GFM) inverters in voltage regulation during large contingency events and optimizing power transactions under normal conditions; and…
Current-fed half bridge converter with bidirectional switches on ac side and a full bridge converter on dc side of a high frequency transformer is an optimal topology for single stage galvanically isolated ac-dc converter for onboard…
In this paper, a non-isolated high step-up dc-dc converter is presented. The proposed converter is composed of an interleaved structure and diode-capacitor multiplier cells for interfacing low-voltage renewable energy sources to…