相关论文: A low-cost, high-speed, very high-order Shack-Hart…
The microfluidic optomechanical resonator (uFOMR) based on a thin-walled glass capillary supports high Q-factor (>1000) mechanical modes in the presence of liquids. In this Letter, the sensitivity of the uFOMR to the surface change is…
To reach the full potential of the new generation of ground based telescopes, an extremely fine adjustment of the phase is required. Wavefront control and correction before detection has therefore become one of the cornerstones of…
Adaptive optics (AO) is a powerful image correction technique with proven benefits for many life-science microscopy methods. However, the complexity of adding a reflective wavefront modulator and a wavefront sensor into already complicated…
The Simons Observatory (SO) is a cosmic microwave background instrumentation suite being deployed in the Atacama Desert in northern Chile. The telescopes within SO use three types of dichroic transition-edge sensor (TES) detector arrays,…
The family of multi-plane phase retrieval sensors, such as the curvature and nonlinear curvature wavefront sensors (WFS), contain tip/tilt information embedded in their signals. We have built a nonlinear curvature WFS to study different…
The ability to form images through hair-thin optical fibres promises to open up new applications from biomedical imaging to industrial inspection. Unfortunately, deployment has been limited because small changes in mechanical deformation…
The wavefront measurement of a light beam is a complex task, which often requires a series of spatially resolved intensity measurements. For instance, a detector array may be used to measure the local phase gradient in the transverse plane…
MagAO-X is the extreme coronagraphic adaptive optics (AO) instrument for the 6.5-meter Magellan Clay telescope and is currently undergoing a comprehensive batch of upgrades. One innovation that the instrument features is a deformable mirror…
Continuous wavefront sensing on future space telescopes allows relaxation of stability requirements while still allowing on-orbit diffraction-limited optical performance. We consider the suitability of phase retrieval to continuously…
The Simons Observatory (SO) is a cosmic microwave background instrumentation suite in the Atacama Desert of Chile. More than 65,000 polarization-sensitive transition-edge sensor (TES) bolometers will be fielded in the frequency range…
Optical interferometers with suspended mirrors are the archetype of all current audio-frequency gravitational-wave detectors. The radiation pressure interaction between the motion of the mirror and the circulating optical field in such…
High-contrast imaging will be a challenge for future ELTs, because their vibrations create low-order aberrations - mostly tip/tilt - that reduce coronagraphic performances at 1.2 lambda/D and above. A Low-Order WaveFront Sensor (LOWFS) is…
Shack-Hartmann wavefront sensors for both solar and laser guide star adaptive optics (with elongated spots) need to observe extended objects. Correlation techniques have been successfully employed to measure the wavefront gradient in solar…
Due to turbulence in the atmosphere images taken from ground-based telescopes become distorted. With adaptive optics (AO) images can be given greater clarity allowing for better observations with existing telescopes and are essential for…
Deformable mirrors with very high order correction generally have smaller dynamic range of motion than what is required to correct seeing over large aperture telescopes. As a result, systems will need to have an architecture that employs…
High throughput, low inner working angle (IWA) phase masks coronagraphs are essential to directly image and characterize (via spectroscopy) earth-like planets. However, the performance of low-IWA coronagraphs is limited by residual pointing…
The Simons Observatory (SO) is a cosmic microwave background (CMB) experiment located in the Atacama Desert in Chile that will make precise temperature and polarization measurements over six spectral bands ranging from 27 to 285 GHz. Three…
The QUIJOTE Experiment was developed to study the polarization in the Cosmic Microwave Background (CMB) over the frequency range of 10-50 GHz. Its first instrument, the Multi Frequency Instrument (MFI), measures in the range 10-20 GHz which…
Optical imperfections, misalignments, aberrations, and even dust can significantly limit sensitivity in high-contrast imaging systems such as coronagraphs. An upstream deformable mirror (DM) in the pupil can be used to correct or compensate…
The success of ground-based instruments for high contrast exoplanet imaging depends on the degree to which adaptive optics (AO) systems can mitigate atmospheric turbulence. While modern AO systems typically suffer from millisecond time lags…