相关论文: Evaluation of the relativistic redshift in frequen…
We report a measurement of the absolute frequency of the 1S0-3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via TAI…
As optical clocks are improved to reach the frequency uncertainty below the 10$^{-17}$ level, the frequency shift due to the blackbody radiation (BBR) has been one of the major systematic effects hindering further improvement. To evaluate…
We measured the absolute frequency of the $^1S_0$ - $^3P_0$ transition of $^{171}$Yb atoms confined in a one-dimensional optical lattice relative to the SI second. The determined frequency was 518 295 836 590 863.38(57) Hz. The uncertainty…
We measured the absolute frequency of the optical clock transition 1S0 (F = 1/2) - 3P0 (F = 1/2) of 171Yb atoms confined in a one-dimensional optical lattice and it was determined to be 518 295 836 590 863.5(8.1) Hz. The frequency was…
We report improved frequency ratio measurement with $^{87}$Sr and $^{171}$Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The $^{87}$Sr optical lattice clock is enhanced with several major modifications and is…
Advanced satellite-based frequency transfers by TWCP and IPPP have been performed between NICT and KRISS. We confirm that the disagreement between them is less than 1x10^{-16} at an averaging time of several days. Additionally, an…
We report improved absolute frequency measurement of the $^{1}$S$_{0}-^{3}$P$_{0}$ transition of $^{171}$Yb at National Metrology Institute of Japan (NMIJ) by comparing the $^{171}$Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary…
The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the…
This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an…
Einstein's theory of general relativity predicts that a clock at a higher gravitational potential will tick faster than an otherwise identical clock at a lower potential, an effect known as the gravitational redshift. Here we perform a…
We have measured the geopotential difference between two locations separated by $457~\mathrm{km}$ by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition…
With 87-Sr atoms confined in a one dimensional optical lattice, the frequency of the optical clock transition 5s^2 ^1S_0 - 5s5p ^3P_0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help…
We evaluated the accuracy limit for estimating gravitational potential using optical lattice clocks by utilizing the quantum Cram\'{e}r--Rao bound. We then compared the results for single-layer and multilayer optical lattice clocks. The…
We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an…
We review our progress in developing a frequency reference with singly ionized lutetium and give estimates of the levels of inaccuracy we expect to achieve in the near future with both the $^1S_0\leftrightarrow{}^3D_1$ and…
According to the Einstein's theory of relativity, the passage of time changes in a gravitational field. On earth, raising a clock by one centimetre increases its tick rate by 1.1 parts in 10$^{18}$, enabling optical clocks to perform…
Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter…
An intercontinental metrological clock comparison between Italy and the Republic of Korea was performed by means of geodetic K-band VLBI observations. The comparison involved the hydrogen masers (H-masers) used at Medicina and Sejong radio…
Additional clock transitions of ytterbium atoms based on inner-shell orbital transition could benefit the search for new physics beyond the Standard Model. Observation of these transitions with high resolution is a prerequisite for making…
In 2022 China Space Station (CSS) will be equipped with atomic clocks and optical clocks with stabilities of $2 \times 10^{-16}$ and $8 \times 10^{-18}$, respectively, which provides an excellent opportunity to test gravitational redshift…