中文
相关论文

相关论文: Unpaired MRI Super Resolution with Contrastive Lea…

200 篇论文

High-resolution (HR) magnetic resonance imaging (MRI) is crucial for many clinical and research applications. However, achieving it remains costly and constrained by technical trade-offs and experimental limitations. Super-resolution (SR)…

Magnetic resonance imaging (MRI) is extensively used for diagnosis and image-guided therapeutics. Due to hardware, physical and physiological limitations, acquisition of high-resolution MRI data takes long scan time at high system cost, and…

医学物理 · 物理学 2018-10-17 Qing Lyu , Chenyu You , Hongming Shan , Ge Wang

In Magnetic Resonance Imaging (MRI), image acquisitions are often undersampled in the measurement domain to accelerate the scanning process, at the expense of image quality. However, image quality is a crucial factor that influences the…

图像与视频处理 · 电气工程与系统科学 2024-05-31 Mevan Ekanayake , Zhifeng Chen , Mehrtash Harandi , Gary Egan , Zhaolin Chen

Recently, the Magnetic Resonance Imaging (MRI) images have limited and unsatisfactory resolutions due to various constraints such as physical, technological and economic considerations. Super-resolution techniques can obtain high-resolution…

计算机视觉与模式识别 · 计算机科学 2019-02-14 Yinghua Li , Bin Song , Jie Guo , Xiaojiang Du , Mohsen Guizani

Magnetic Resonance Imaging (MRI) is important in clinic to produce high resolution images for diagnosis, but its acquisition time is long for high resolution images. Deep learning based MRI super resolution methods can reduce scan time…

图像与视频处理 · 电气工程与系统科学 2022-09-08 Ziyan Lin , Zihao Chen

Magnetic resonance imaging (MRI) is widely used for screening, diagnosis, image-guided therapy, and scientific research. A significant advantage of MRI over other imaging modalities such as computed tomography (CT) and nuclear imaging is…

图像与视频处理 · 电气工程与系统科学 2020-02-20 Qing Lyu , Hongming Shan , Ge Wang

High resolution magnetic resonance~(MR) imaging~(MRI) is desirable in many clinical applications, however, there is a trade-off between resolution, speed of acquisition, and noise. It is common for MR images to have worse through-plane…

图像与视频处理 · 电气工程与系统科学 2018-02-27 Can Zhao , Aaron Carass , Blake E. Dewey , Jerry L. Prince

Magnetic resonance imaging (MRI) is a widely used medical imaging modality. However, due to the limitations in hardware, scan time, and throughput, it is often clinically challenging to obtain high-quality MR images. The super-resolution…

图像与视频处理 · 电气工程与系统科学 2020-02-20 Qing Lyu , Hongming Shan , Ge Wang

While functional Magnetic Resonance Imaging (fMRI) offers valuable insights into cognitive processes, its inherent spatial limitations pose challenges for detailed analysis of the fine-grained functional architecture of the brain. More…

图像与视频处理 · 电气工程与系统科学 2025-02-25 Fernando Pérez-Bueno , Hongwei Bran Li , Matthew S. Rosen , Shahin Nasr , Cesar Caballero-Gaudes , Juan Eugenio Iglesias

Deep learning has demonstrated strong potential for MRI reconstruction. However, conventional supervised learning requires high-quality, high-SNR references for network training, which are often difficult or impossible to obtain in…

图像与视频处理 · 电气工程与系统科学 2026-01-01 Haoyang Pei , Nikola Janjuvsevic , Renqing Luo , Ding Xia , Xiang Xu , William Moore , Yao Wang , Hersh Chandarana , Li Feng

Magnetic Resonance Imaging (MRI) has become an important technique in the clinic for the visualization, detection, and diagnosis of various diseases. However, one bottleneck limitation of MRI is the relatively slow data acquisition process.…

图像与视频处理 · 电气工程与系统科学 2022-11-28 Xue Liu , Juan Zou , Xiawu Zheng , Cheng Li , Hairong Zheng , Shanshan Wang

Improving the image resolution and acquisition speed of magnetic resonance imaging (MRI) is a challenging problem. There are mainly two strategies dealing with the speed-resolution trade-off: (1) $k$-space undersampling with high-resolution…

计算机视觉与模式识别 · 计算机科学 2021-04-14 Wenqi Huang , Sen Jia , Ziwen Ke , Zhuo-Xu Cui , Jing Cheng , Yanjie Zhu , Dong Liang

High-resolution (HR) magnetic resonance imaging is critical in aiding doctors in their diagnoses and image-guided treatments. However, acquiring HR images can be time-consuming and costly. Consequently, deep learning-based super-resolution…

图像与视频处理 · 电气工程与系统科学 2024-10-21 Jianan Liu , Hao Li , Tao Huang , Euijoon Ahn , Kang Han , Adeel Razi , Wei Xiang , Jinman Kim , David Dagan Feng

Multi-contrast super-resolution (MCSR) is crucial for enhancing MRI but current deep learning methods are limited. They typically require large, paired low- and high-resolution (LR/HR) training datasets, which are scarce, and are trained…

计算机视觉与模式识别 · 计算机科学 2026-01-26 Yinzhe Wu , Hongyu Rui , Fanwen Wang , Jiahao Huang , Zhenxuan Zhang , Haosen Zhang , Zi Wang , Guang Yang

Magnetic resonance imaging (MRI) reconstruction is a fundamental task aimed at recovering high-quality images from undersampled or low-quality MRI data. This process enhances diagnostic accuracy and optimizes clinical applications. In…

图像与视频处理 · 电气工程与系统科学 2025-03-11 Xiaoyan Kui , Zijie Fan , Zexin Ji , Qinsong Li , Chengtao Liu , Weixin Si , Beiji Zou

Clinical routine and retrospective cohorts commonly include multi-parametric Magnetic Resonance Imaging; however, they are mostly acquired in different anisotropic 2D views due to signal-to-noise-ratio and scan-time constraints. Thus…

Limited by imaging systems, the reconstruction of Magnetic Resonance Imaging (MRI) images from partial measurement is essential to medical imaging research. Benefiting from the diverse and complementary information of multi-contrast MR…

图像与视频处理 · 电气工程与系统科学 2023-07-11 Jiamiao Zhang , Yichen Chi , Jun Lyu , Wenming Yang , Yapeng Tian

Magnetic Resonance Imaging (MRI) is a leading diagnostic modality for a wide range of exams, where multiple contrast images are often acquired for characterizing different tissues. However, acquiring high-resolution MRI typically extends…

图像与视频处理 · 电气工程与系统科学 2024-08-07 Shaoming Zheng , Yinsong Wang , Siyi Du , Chen Qin

High-quality magnetic resonance (MR) image, i.e., with near isotropic voxel spacing, is desirable in various scenarios of medical image analysis. However, many MR acquisitions use large inter-slice spacing in clinical practice. In this…

图像与视频处理 · 电气工程与系统科学 2021-08-18 Kai Xuan , Liping Si , Lichi Zhang , Zhong Xue , Yining Jiao , Weiwu Yao , Dinggang Shen , Dijia Wu , Qian Wang

Using single-task deep learning methods to reconstruct Magnetic Resonance Imaging (MRI) data acquired with different imaging sequences is inherently challenging. The trained deep learning model typically lacks generalizability, and the…

图像与视频处理 · 电气工程与系统科学 2024-04-23 Wanyu Bian , Albert Jang , Fang Liu
‹ 上一页 1 2 3 10 下一页 ›