相关论文: One In-Situ Extraction Algorithm for Monitoring Bu…
The 4 electrode signals of the beam position detector(BPM) of the STORAGE ring of HEFEI Light Source are directly connected to the domestic oscilloscope with 12bit resolution, 10Gsps sampling rate and 2GHz bandwidth. The acquisition program…
Hefei Light Source (HLS) is being upgraded to HLS II. Its emittance will be much lower than before, therefore the Touschek scattering will increase significantly and become the dominant factor of beam loss. So it is necessary to build a new…
A logarithm processing algorithm to measure beam transverse size and position is proposed and preliminary experimental results in Hefei Light Source II (HLS II) are given. The algorithm is based on only 4 successive channels of 16 anode…
This contribution presents a novel bunch current measurement system based on an ultra-fast photodetector and a high-speed digitizer at Hefei Light Source II (HLS II). In order to achieve bunch-by-bunch resolution, the sampling rate of the…
The upgrade project of Hefei Light Source storage ring is under way. In this paper, the wake fields of new designed vacuum chambers have been simulated by CST code, and then broadband impedances were obtained by FFT. Together with resistive…
A system was developed for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations based on the signal from a single beam-position monitor (BPM) located in a region of the ring with large amplitude functions. The…
An interferometer system and an imaging system using visible synchrotron radiation (SR) have been installed in HLS II storage ring. Simulations of these two systems are given using Synchrotron Radiation Workshop(SRW) code. With these two…
Aligning beamlines at synchrotron light sources is a high-dimensional, expensive-to-sample optimization problem, as beams are focused using a series of dynamic optical components. Bayesian Optimization is an efficient machine learning…
The upgrade project of Hefei Light Source storage ring is under way. In this paper, the broadband impedances of resistive wall and coated ceramic vacuum chamber were calculated using the analytic formula, the wake fields and impedances of…
Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…
The first two years of user service of the third generation light source BESSY II emphasized the importance of a reliable, comprehensive and dense logging of a few thousand setpoints, readbacks, status and alarm values. Today data from…
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring…
We address the problem of super-resolution of point sources from binary measurements, where random projections of the blurred measurement of the actual signal are encoded using only the sign information. The threshold used for binary…
Double rf systems are critical for achieving the parameters of 4th-generation light sources. These systems, comprising both main and harmonic rf cavities, relax statistical collective effects but also introduce instabilities, such as…
Blind source separation (BSS) algorithms are unsupervised methods, which are the cornerstone of hyperspectral data analysis by allowing for physically meaningful data decompositions. BSS problems being ill-posed, the resolution requires…
A scheme with two superconducting RF cavities (sc-cavities) is designed to upgrade electron storage rings with odd buckets into multi-length bunches. In this paper, Hefei Light Source II (HLS II) is given as an example for odd buckets. In…
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…
We present two new source extraction methods, based on Bayesian model selection and using the Bayesian Information Criterion (BIC). The first is a source detection filter, able to simultaneously detect point sources and estimate the image…
Dedicated optics with extremely short electron bunches enable synchrotron light sources to generate intense coherent THz radiation. The high degree of spatial compression in this so-called low-alpha optics entails a complex longitudinal…
With a Bayesian Gaussian regression approach, a systematic method for analyzing a storage ring's beam position monitor (BPM) system requirements has been developed. The ultimate performance of a ring-based accelerator, based on brightness…