中文
相关论文

相关论文: Multi-stage Deep Learning Artifact Reduction for P…

200 篇论文

This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…

计算工程、金融与科学 · 计算机科学 2020-10-09 T. Bayaraa , C. M. Hyun , T. J. Jang , S. M. Lee , J. K. Seo

The rise of deep learning has introduced a transformative era in the field of image processing, particularly in the context of computed tomography. Deep learning has made a significant contribution to the field of industrial Computed…

计算机视觉与模式识别 · 计算机科学 2024-01-30 Yuzhong Zhou , Linda-Sophie Schneider , Fuxin Fan , Andreas Maier

Multi-scale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (CT) instruments are one of…

图像与视频处理 · 电气工程与系统科学 2022-01-12 S. V. Venkatakrishnan , K. Aditya Mohan , Amir Koushyar Ziabari , Charles A. Bouman

Three-dimensional (3D) reconstruction of head Computed Tomography (CT) images elucidates the intricate spatial relationships of tissue structures, thereby assisting in accurate diagnosis. Nonetheless, securing an optimal head CT scan…

计算机视觉与模式识别 · 计算机科学 2023-09-18 Bowen Zheng , Chenxi Huang , Yuemei Luo

Cone beam computed tomography (CBCT) images can be used for dose calculation in adaptive radiation therapy (ART). The main challenges are the large artefacts and inaccurate Hounsfield unit (HU) values. Currently, deformed planning CT images…

医学物理 · 物理学 2019-09-04 Xiao Liang , Liyuan Chen , Dan Nguyen , Zhiguo Zhou , Xuejun Gu , Ming Yang , Jing Wang , Steve Jiang

Assume you encounter an inverse problem that shall be solved for a large number of data, but no ground-truth data is available. To emulate this encounter, in this study, we assume it is unknown how to solve the imaging problem of Computed…

Cone-Beam Computed Tomography (CBCT) is widely used for real-time intraoperative imaging due to its low radiation dose and high acquisition speed. However, despite its high resolution, CBCT suffers from significant artifacts and thereby…

图像与视频处理 · 电气工程与系统科学 2025-06-11 Maximilian Tschuchnig , Lukas Lamminger , Philipp Steininger , Michael Gadermayr

This is a preprint. The latest version has been published here: https://pubs.rsna.org/doi/10.1148/ryai.230275 Purpose: Sparse-view computed tomography (CT) is an effective way to reduce dose by lowering the total number of views acquired,…

图像与视频处理 · 电气工程与系统科学 2024-08-09 Johannes Thalhammer , Manuel Schultheiss , Tina Dorosti , Tobias Lasser , Franz Pfeiffer , Daniela Pfeiffer , Florian Schaff

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

信号处理 · 电气工程与系统科学 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Deep learning has shown great promise for CT image reconstruction, in particular to enable low dose imaging and integrated diagnostics. These merits, however, stand at great odds with the low availability of diverse image data which are…

计算机视觉与模式识别 · 计算机科学 2021-03-23 Arjun Krishna , Kedar Bartake , Chuang Niu , Ge Wang , Youfang Lai , Xun Jia , Klaus Mueller

Histopathology is a gold standard for cancer diagnosis under a microscopic examination. However, histological tissue processing procedures result in artifacts, which are ultimately transferred to the digitized version of glass slides, known…

In clinical CT, the x-ray source emits polychromatic x-rays, which are detected in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral model on the basis of the Beer-Lambert…

医学物理 · 物理学 2018-01-11 Wenxiang Cong , Ge Wang

Computed tomography has propelled scientific advances in fields from biology to materials science. This technology allows for the elucidation of 3-dimensional internal structure by the attenuation of x-rays through an object at different…

计算机视觉与模式识别 · 计算机科学 2022-11-02 Rey Mendoza , Minh Nguyen , Judith Weng Zhu , Vincent Dumont , Talita Perciano , Juliane Mueller , Vidya Ganapati

This is an article about the Computed Tomography (CT) and how Deep Learning influences CT reconstruction pipeline, especially in low dose scenarios.

图像与视频处理 · 电气工程与系统科学 2019-04-09 Shabab Bazrafkan , Vincent Van Nieuwenhove , Joris Soons , Jan De Beenhouwer , Jan Sijbers

Deep neural networks have received considerable attention in clinical imaging, particularly with respect to the reduction of radiation risk. Lowering the radiation dose by reducing the photon flux inevitably results in the degradation of…

图像与视频处理 · 电气工程与系统科学 2021-09-14 Khalid L. Alsamadony , Ertugrul U. Yildirim , Guenther Glatz , Umair bin Waheed , Sherif M. Hanafy

An approach to incorporate deep learning within an iterative image reconstruction framework to reconstruct images from severely incomplete measurement data is presented. Specifically, we utilize a convolutional neural network (CNN) as a…

计算机视觉与模式识别 · 计算机科学 2017-09-05 Brendan Kelly , Thomas P. Matthews , Mark A. Anastasio

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

图像与视频处理 · 电气工程与系统科学 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

Artifacts are a common occurrence in Diffusion MRI (dMRI) scans. Identifying and removing them is essential to ensure the accuracy and viability of any post processing carried out on these scans. This makes QC (quality control) a crucial…

图像与视频处理 · 电气工程与系统科学 2021-03-10 Adnan Ahmad , Drew Parker , Zahra Riahi Samani , Ragini Verma

Image guidance for minimally invasive interventions is usually performed by acquiring fluoroscopic images using a C-arm system. However, the projective data provide only limited information about the spatial structure and position of…