中文
相关论文

相关论文: ASCON: Anatomy-aware Supervised Contrastive Learni…

200 篇论文

To reduce radiation exposure and improve the diagnostic efficacy of low-dose computed tomography (LDCT), numerous deep learning-based denoising methods have been developed to mitigate noise and artifacts. However, most of these approaches…

图像与视频处理 · 电气工程与系统科学 2025-08-12 Runze Wang , Zeli Chen , Zhiyun Song , Wei Fang , Jiajin Zhang , Danyang Tu , Yuxing Tang , Minfeng Xu , Xianghua Ye , Le Lu , Dakai Jin

Denoising low-dose computed tomography (CT) images is a critical task in medical image computing. Supervised deep learning-based approaches have made significant advancements in this area in recent years. However, these methods typically…

图像与视频处理 · 电气工程与系统科学 2023-07-17 Xuan Liu , Yaoqin Xie , Jun Cheng , Songhui Diao , Shan Tan , Xiaokun Liang

With the development of deep learning, medical image processing has been widely used to assist clinical research. This paper focuses on the denoising problem of low-dose computed tomography using deep learning. Although low-dose computed…

图像与视频处理 · 电气工程与系统科学 2026-05-19 Zhilin Guan , Wei Zhang

Low Dose CT Denoising research aims to reduce the risks of radiation exposure to patients. Recently researchers have used deep learning to denoise low dose CT images with promising results. However, approaches that use mean-squared-error…

图像与视频处理 · 电气工程与系统科学 2024-09-05 Sepehr Ataei , Javad Alirezaie , Paul Babyn

Deep learning has been successfully applied to low-dose CT (LDCT) image denoising for reducing potential radiation risk. However, the widely reported supervised LDCT denoising networks require a training set of paired images, which is…

机器学习 · 计算机科学 2023-02-09 Yuhui Ruan , Qiao Yuan , Chuang Niu , Chen Li , Yudong Yao , Ge Wang , Yueyang Teng

In coronary CT angiography, a series of CT images are taken at different levels of radiation dose during the examination. Although this reduces the total radiation dose, the image quality during the low-dose phases is significantly…

计算机视觉与模式识别 · 计算机科学 2019-03-06 Eunhee Kang , Hyun Jung Koo , Dong Hyun Yang , Joon Bum Seo , Jong Chul Ye

Fluoroscopy is critical for real-time X-ray visualization in medical imaging. However, low-dose images are compromised by noise, potentially affecting diagnostic accuracy. Noise reduction is crucial for maintaining image quality, especially…

图像与视频处理 · 电气工程与系统科学 2024-11-05 Sun-Young Jeon , Sen Wang , Adam S. Wang , Garry E. Gold , Jang-Hwan Choi

Image classification is hindered by subtle inter-class differences and substantial intra-class variations, which limit the effectiveness of existing contrastive learning methods. Supervised contrastive approaches based on the InfoNCE loss…

计算机视觉与模式识别 · 计算机科学 2025-12-23 Bin Wang , Fadi Dornaika

The explosive rise of the use of Computer tomography (CT) imaging in medical practice has heightened public concern over the patient's associated radiation dose. However, reducing the radiation dose leads to increased noise and artifacts,…

计算机视觉与模式识别 · 计算机科学 2021-07-06 Sutanu Bera , Prabir Kumar Biswas

Self-supervised pre-training of deep learning models with contrastive learning is a widely used technique in image analysis. Current findings indicate a strong potential for contrastive pre-training on medical images. However, further…

图像与视频处理 · 电气工程与系统科学 2024-10-21 Daniel Wolf , Tristan Payer , Catharina Silvia Lisson , Christoph Gerhard Lisson , Meinrad Beer , Michael Götz , Timo Ropinski

Deep learning has achieved great success in recent years with the aid of advanced neural network structures and large-scale human-annotated datasets. However, it is often costly and difficult to accurately and efficiently annotate…

计算机视觉与模式识别 · 计算机科学 2023-03-23 Chen Feng , Ioannis Patras

LDCT has drawn major attention in the medical imaging field due to the potential health risks of CT-associated X-ray radiation to patients. Reducing the radiation dose, however, decreases the quality of the reconstructed images, which…

图像与视频处理 · 电气工程与系统科学 2022-04-19 Zhizhong Huang , Junping Zhang , Yi Zhang , Hongming Shan

Reducing the radiation exposure for patients in Total-body CT scans has attracted extensive attention in the medical imaging community. Given the fact that low radiation dose may result in increased noise and artifacts, which greatly…

图像与视频处理 · 电气工程与系统科学 2023-07-19 Minghan Fu , Yanhua Duan , Zhaoping Cheng , Wenjian Qin , Ying Wang , Dong Liang , Zhanli Hu

Given a similarity metric, contrastive methods learn a representation in which examples that are similar are pushed together and examples that are dissimilar are pulled apart. Contrastive learning techniques have been utilized extensively…

机器学习 · 计算机科学 2023-07-07 Emily Mu , John Guttag , Maggie Makar

Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance for medical image segmentation, yet need plenty of manual annotations for training. Semi-Supervised Learning (SSL) methods are promising to reduce the…

计算机视觉与模式识别 · 计算机科学 2022-08-19 Ran Gu , Jingyang Zhang , Guotai Wang , Wenhui Lei , Tao Song , Xiaofan Zhang , Kang Li , Shaoting Zhang

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

图像与视频处理 · 电气工程与系统科学 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

Low-dose computed tomography (CT) has attracted a major attention in the medical imaging field, since CT-associated x-ray radiation carries health risks for patients. The reduction of CT radiation dose, however, compromises the…

计算机视觉与模式识别 · 计算机科学 2019-07-16 Hongming Shan , Yi Zhang , Qingsong Yang , Uwe Kruger , Mannudeep K. Kalra , Ling Sun , Wenxiang Cong , Ge Wang

Recently, Self-supervised learning methods able to perform image denoising without ground truth labels have been proposed. These methods create low-quality images by adding random or Gaussian noise to images and then train a model for…

图像与视频处理 · 电气工程与系统科学 2021-04-07 Dongkyu Won , Euijin Jung , Sion An , Philip Chikontwe , Sang Hyun Park

Computed Tomography (CT) imposes risk on the patients due to its inherent X-ray radiation, stimulating the development of low-dose CT (LDCT) imaging methods. Lowering the radiation dose reduces the health risks but leads to noisier…

图像与视频处理 · 电气工程与系统科学 2022-11-03 Elvira Zainulina , Alexey Chernyavskiy , Dmitry V. Dylov

Noise in low-dose computed tomography (LDCT) can obscure important diagnostic details. While deep learning offers powerful denoising, supervised methods require impractical paired data, and self-supervised alternatives often use opaque,…

图像与视频处理 · 电气工程与系统科学 2026-02-19 Yipeng Sun , Linda-Sophie Schneider , Siyuan Mei , Jinhua Wang , Ge Hu , Mingxuan Gu , Chengze Ye , Fabian Wagner , Lan Song , Siming Bayer , Andreas Maier
‹ 上一页 1 2 3 10 下一页 ›