相关论文: Angular dependence of the electrically driven and …
The dynamic magnetic susceptibility of magnetic materials near ferromagnetic resonance (FMR) is very important in interpreting dc-voltage in electrical detection of FMR. Based on the causality principle and the assumption that the usual…
We observe a dc voltage peak at ferromagnetic resonance (FMR) in samples consisting of a single ferromagnetic (FM) layer grown epitaxially on the $\mathit{n-}$GaAs (001) surface. The FMR peak is detected as an interfacial voltage with a…
Employing a broadband microwave reflection configuration, we have measured the complex surface impedance, $Z_S(\omega,T,H)$, of single crystal La$_{0.8}$Sr$_{0.2}$MnO$_3$, as a function of frequency (0.045-45 GHz), temperature (250-325 K),…
We investigate the impact of microwave excited spin excitations on the DC charge transport in a ferromagnetic (FM) grating. We observe both resonant and nonresonant microwave photoresistance. Resonant features are identified as the…
We investigate the dc electric response induced by ferromagnetic resonance in ferromagnetic Permalloy (Ni80Fe20) microstrips. The resulting magnetization precession alters the angle of the magnetization with respect to both dc and rf…
We have measured the angular dependence of ferromagnetic resonance (FMR) spectra for Fibonacci-distorted, Kagome artificial spin ice (ASI). The number of strong modes in the FMR spectra depend on the orientation of the applied DC magnetic…
This work reviews and examines two particular issues related with the new technique of electrical detection of ferromagnetic resonance (FMR). This powerful technique has been broadly applied for studying magnetization and spin dynamics over…
We demonstrate a scalable new ferromagnetic resonance (FMR) technique based on the spin-orbit interaction. An alternating current drives FMR in uniform ferromagnetic structures patterned from the dilute magnetic semiconductors (Ga,Mn)As and…
We present an experimental study of the effects of driving current direction on ferromagnetic resonance in NiFe foils. The rf driving current was applied to NiFe foils of different shapes. In rectangular samples with a close-to-uniform flow…
Surface acoustic waves (SAW) in the GHz frequency range are exploited for the all-elastic excitation and detection of ferromagnetic resonance (FMR) in a ferromagnetic/ferroelectric (nickel/lithium niobate) hybrid device. We measure the SAW…
Ferromagnetic resonance (FMR) is a fundamental technique for probing magnetization dynamics in spintronic and magnetic materials. However, conventional FMR measurements rely on broadband vector network analyzers (VNAs), whose high cost…
In this work we introduce a new method of a ferromagnetic resonance (FMR) detection from thin, nm-size, films. Our setup is based on the commercial piezo-cantilever, used for atomic force microscopy. It has an option to rotate the sample in…
Measurements of ferromagnetic resonance (FMR) are pivotal to modern magnetism and spintronics. Recently, we reported on the Ferris FMR technique, which relies on large-amplitude modulation of the externally applied magnetic field. It was…
We report detailed angle-dependent studies of the microwave (f=50 to 90 GHz) interlayer magneto-electrodynamics of a single crystal sample of the organic charge-density-wave (CDW) conductor alpha-(BEDT-TTF)2KHg(SCN)4. Recently developed…
The electrical detection of spin torque ferromagnetic resonance (st-FMR) is becoming a popular method for measuring the spin-Hall angle of heavy metals (HM). However, various sensible analysis on the same material with either the same or…
We experimentally image the magnetic precession phase of patterned spin Hall multilayer samples to study the rf driving field vector using time-resolved anomalous Nernst effect (TRANE) microscopy. Our ferromagnetic resonance (FMR)…
We present Magnetic Resonance Force Microscopy (MRFM) measurements of Ferromagnetic Resonance (FMR) in a 50 nm thick permalloy film, tilted with respect to the direction of the external magnetic field. At small probe-sample distances the…
The broadband ferromagnetic resonance measurement using the rectifying effect of Ni81Fe19 wire has been investigated. One wire is deposited on the center strip line of the coplanar waveguide (CPW) and the other one deposited between two…
We measured ferromagnetic resonance of a single submicron ferromagnetic strip, embedded in an on-chip microwave transmission line device. The method used is based on detection of the oscillating magnetic flux due to the magnetization…
A ferromagnet can resonantly absorbs rf radiation to sustain a steady precession of the magnetization around an internal or applied magnetic field. We show that under these ferromagnetic resonance (FMR) conditions, a dc voltage is generated…