相关论文: Proactive and Automatic Underfrequency Load Sheddi…
The paper describes a distributed under-frequency load shedding and load restoration scheme, that exploits frequency and Rate-of-Change-of-Frequency (ROCOF) measurements produced by Phasor Measurement Units (PMUs) as detectors of a large…
Under-frequency load shedding (UFLS) prevents system collapse during large disturbances. Increased penetration of distributed energy resources (DERs) and reduced system inertia makes it challenging to design a static UFLS scheme, which…
This paper introduces under-frequency load shedding (UFLS) schemes specially designed to fulfill the power reserve requirements in islanded microgrids (MGs), where only one grid-forming resource is available for frequency regulation. When…
Under frequency load shedding (UFLS) constitutes the very last resort for preventing total blackouts and cascading events. Fluctuating operating conditions and weak resilience of the future grid require UFLS strategies adapt to various…
High penetration of renewable resources results in a power system with lower inertia and higher frequency sensitivity to power imbalances. Such systems are becoming increasingly susceptible to frequency collapse during extreme disturbances.…
This paper presents a data-driven methodology for estimating Under Frequency Load Shedding (UFLS) in small power systems. UFLS plays a vital role in maintaining system stability by shedding load when the frequency drops below a specified…
In modern power systems, the Rate-of-Change-of-Frequency (ROCOF) may be largely employed in Wide Area Monitoring, Protection and Control (WAMPAC) applications. However, a standard approach towards ROCOF measurements is still missing. In…
Today's evolving power system contains an increasing amount of power electronic interfaced energy sources and loads that require a paradigm shift in utility operations. Sub-synchronous oscillations at frequencies around 13-15 Hz, for…
Under-Frequency Load Shedding (UFLS) schemes are the last resort to contain a frequency drop in the grid by disconnecting part of the demand. The allocation methods for selecting feeders that would contribute to the UFLS scheme have…
Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…
The frequency-weighted model order reduction techniques are used to find a lower-order approximation of the high-order system that exhibits high-fidelity within the frequency region emphasized by the frequency weights. In this paper, we…
Real-time transmission line outage detection is difficult because of partial phasor measurement unit (PMU) deployment and varying outage signal strength. Existing detection approaches focus on monitoring PMU-measured nodal algebraic states,…
In this paper, we devise a scheduling algorithm for ordering transmission of synchrophasor data from the substation to the control center in as short a time frame as possible, within the realtime hierarchical communications infrastructure…
With the proposition to install a large number of phasor measurement units (PMUs) in the future power grid, it is essential to provide robust communications infrastructure for phasor data across the network. We make progress in this…
Due to the limited generation and finite inertia, microgrid suffers from the large frequency and voltage deviation which can lead to system collapse. Thus, reliable load shedding to keep frequency stable is required. Wireless network,…
In this paper, a novel method to estimate dynamic load parameters via ambient PMU measurements is proposed. Unlike conventional parameter identification methods, the proposed algorithm does not require the existence of large disturbance to…
In the electric system, extreme weather events can cause trips or physical damage to transmission lines, leading to large-scale load shedding. To mitigate power shedding, we propose a framework that pre-positions the commitment of…
Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…
Low levels of inertia due to increasing renewable penetration bring several challenges, such as the higher need for Primary Frequency Response (PFR). A potential solution to mitigate this problem consists on reducing the largest possible…
The proliferation of phasor measurement units (PMUs) into electric power distribution grids presents new opportunities for utility operators to manage distribution systems more effectively. One potential application of PMU measurements is…