中文
相关论文

相关论文: TriDoNet: A Triple Domain Model-driven Network for…

200 篇论文

For the task of metal artifact reduction (MAR), although deep learning (DL)-based methods have achieved promising performances, most of them suffer from two problems: 1) the CT imaging geometry constraint is not fully embedded into the…

图像与视频处理 · 电气工程与系统科学 2021-09-14 Hong Wang , Yuexiang Li , Haimiao Zhang , Jiawei Chen , Kai Ma , Deyu Meng , Yefeng Zheng

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

图像与视频处理 · 电气工程与系统科学 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

Recently, both supervised and unsupervised deep learning methods have been widely applied on the CT metal artifact reduction (MAR) task. Supervised methods such as Dual Domain Network (Du-DoNet) work well on simulation data; however, their…

图像与视频处理 · 电气工程与系统科学 2021-03-10 Yuanyuan Lyu , Jiajun Fu , Cheng Peng , S. Kevin Zhou

During the computed tomography (CT) imaging process, metallic implants within patients often cause harmful artifacts, which adversely degrade the visual quality of reconstructed CT images and negatively affect the subsequent clinical…

图像与视频处理 · 电气工程与系统科学 2022-12-27 Hong Wang , Yuexiang Li , Haimiao Zhang , Deyu Meng , Yefeng Zheng

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

医学物理 · 物理学 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

Metal implants and other high-density objects in patients introduce severe streaking artifacts in CT images, compromising image quality and diagnostic performance. Although various methods were developed for CT metal artifact reduction over…

图像与视频处理 · 电气工程与系统科学 2024-01-10 Zilong Li , Qi Gao , Yaping Wu , Chuang Niu , Junping Zhang , Meiyun Wang , Ge Wang , Hongming Shan

Inspired by the great success of deep neural networks, learning-based methods have gained promising performances for metal artifact reduction (MAR) in computed tomography (CT) images. However, most of the existing approaches put less…

图像与视频处理 · 电气工程与系统科学 2025-08-04 Hong Wang , Yuexiang Li , Deyu Meng , Yefeng Zheng

Deep neural network based methods have achieved promising results for CT metal artifact reduction (MAR), most of which use many synthesized paired images for training. As synthesized metal artifacts in CT images may not accurately reflect…

图像与视频处理 · 电气工程与系统科学 2020-07-09 Chuang Niu , Wenxiang Cong , Fenglei Fan , Hongming Shan , Mengzhou Li , Jimin Liang , Ge Wang

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

图像与视频处理 · 电气工程与系统科学 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

Metal artifacts caused by the presence of metallic implants tremendously degrade the reconstructed computed tomography (CT) image quality, affecting clinical diagnosis or reducing the accuracy of organ delineation and dose calculation in…

Due to the presence of metallic implants, the imaging quality of computed tomography (CT) would be heavily degraded. With the rapid development of deep learning, several network models have been proposed for metal artifact reduction (MAR).…

医学物理 · 物理学 2021-04-06 Tao Wang , Wenjun Xia , Zexin Lu , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

Metal artefacts in CT images may disrupt image quality and interfere with diagnosis. Recently many deep-learning-based CT metal artefact reduction (MAR) methods have been proposed. Current deep MAR methods may be troubled with domain gap…

计算机视觉与模式识别 · 计算机科学 2021-11-29 Muge Du , Kaichao Liang , Yinong Liu , Yuxiang Xing

Metal artifacts in computed tomography (CT) severely degrade image quality, compromising diagnostic accuracy and radiotherapy planning, especially in cancer patients with high-density implants. We propose H3D-MarNet, a two-stage framework…

计算机视觉与模式识别 · 计算机科学 2026-05-13 Mubashara Rehman , Niki Martinel , Michele Avanzo , Riccardo Spizzo , Christian Micheloni

Current deep neural network based approaches to computed tomography (CT) metal artifact reduction (MAR) are supervised methods which rely heavily on synthesized data for training. However, as synthesized data may not perfectly simulate the…

图像与视频处理 · 电气工程与系统科学 2019-12-02 Haofu Liao , Wei-An Lin , Jianbo Yuan , S. Kevin Zhou , Jiebo Luo

Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal…

图像与视频处理 · 电气工程与系统科学 2020-09-17 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Lei Xing

Metal artifacts, caused by high-density metallic implants in computed tomography (CT) imaging, severely degrade image quality, complicating diagnosis and treatment planning. While existing deep learning algorithms have achieved notable…

计算机视觉与模式识别 · 计算机科学 2025-08-15 Farid Tasharofi , Fuxin Fan , Melika Qahqaie , Mareike Thies , Andreas Maier

The reduction of metal artifacts in computed tomography (CT) images, specifically for strong artifacts generated from multiple metal objects, is a challenging issue in medical imaging research. Although there have been some studies on…

图像与视频处理 · 电气工程与系统科学 2020-08-24 Megumi Nakao , Keiho Imanishi , Nobuhiro Ueda , Yuichiro Imai , Tadaaki Kirita , Tetsuya Matsuda

During the process of computed tomography (CT), metallic implants often cause disruptive artifacts in the reconstructed images, impeding accurate diagnosis. Several supervised deep learning-based approaches have been proposed for reducing…

图像与视频处理 · 电气工程与系统科学 2024-01-08 Xuan Liu , Yaoqin Xie , Songhui Diao , Shan Tan , Xiaokun Liang

Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…

Due to the wide applications of X-ray computed tomography (CT) in medical imaging activities, radiation exposure has become a major concern for public health. Sparse-view CT is a promising approach to reduce the radiation dose by…

‹ 上一页 1 2 3 10 下一页 ›