相关论文: A transportable clock laser system with an instabi…
Optical clocks require an ultra-stable laser to probe and precisely measure the frequency of the narrow-linewidth clock transition. We introduce a portable ultraviolet (UV) laser system for use in an aluminum quantum logic clock,…
We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and…
We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a…
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to…
The development of an optical clock with ultimate accuracy and stability requires lasers with very narrow linewidth. We present two ultrastable laser systems based on 48 cm long Fabry-Perot cavities made of ULE glass in horizontal and…
The superb precision of an atomic clock is derived from its stability. Atomic clocks based on optical (rather than microwave) frequencies are attractive because of their potential for high stability, which scales with operational frequency.…
We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to…
Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity…
We report on a laser locked to a silicon cavity operating continuously at 4 K with $1 \times 10^{-16}$ instability and a median linewidth of 17 mHz at 1542 nm. This is a ten-fold improvement in short-term instability, and a $10^4$…
We have developed an ultra-stable source in the deep ultraviolet, suitable to fulfill the interrogation requirements of a future fully-operational lattice clock based on neutral mercury. At the core of the system is a Fabry-P\'erot cavity…
We present an in-vacuum bonded, 9.7 mL-volume Fabry-P\'erot ultrastable optical reference cavity that operates without a vacuum enclosure. A laser stabilized to the cavity demonstrates low, thermal noise-limited phase noise and 5x10^{-14}…
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an ultrastable laser to this ultranarrow clock transition and…
Lasers stabilized to vacuum-gap Fabry-P\'erot optical reference cavities display extraordinarily low noise and high stability, with linewidths much less than 1 Hz. These lasers can expand into new applications and ubiquitous use with the…
We develop and demonstrate a compact (less than $6$ mL) portable Fabry-P\'{e}rot optical reference cavity. A laser locked to the cavity is thermal noise limited at $2\times10^{-14}$ fractional frequency stability. Broadband feedback control…
We report on the development and performance evaluation of an ultra-stable clock laser for an $\rm ^{27}Al^+$ optical clock. The thermal noise limited ultra-stable laser is developed based on a 30 cm long ultra-stable cavity. Three…
Crystalline optical cavities are the foundation of today's state-of-the-art ultrastable lasers. Building on our previous silicon cavity effort, we now achieve the fundamental thermal noise-limited stability for a 6 cm long silicon cavity…
We report on two ultrastable lasers each stabilized to independent silicon Fabry-P\'erot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of…
We demonstrate a vacuum-gap ultrastable optical reference cavity that does not require a vacuum enclosure. Our simple method of optical contact bonding in a vacuum environment allows for cavity operation in air while maintaining vacuum…
We present the design and realization of two reference cavities for ultra-stable lasers addressing narrow transitions in mixed-species (In+ / Yb+) Coulomb crystals. With a simple setup, we achieve a fractional frequency instability close to…
Cryogenic ultra-stable lasers have extremely low thermal noise limits and frequency drifts, but they are more seriously affected by vibration noise from cryostats. Main material candidates for cryogenic ultra-stable cavities include silicon…