Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy…
A high precision beam monitor system based on silicon carbide PIN sensor is designed for China Spallation Neutron Source 1.6 GeV proton beam to monitor the proton beam fluence.The concept design of the beam monitor system is finished…
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…
A proton irradiation site for silicon detectors has been developed and commissioned at the Bonn Isochronous Cyclotron. The accelerator provides 14 MeV proton beams of up to 1 $\mu$A at beam widths of a few mm to the setup. Devices Under…
Medical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as microdosimetry and ion imaging, precise knowledge of…
An instrument has been developed for precision controlled exposures of electronic devices and material samples in particle beams. The instrument provides simultaneously a real time record of the profile of the beam and the fluence received.…
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a…
This paper presents a millimeter-scale CMOS 64$\times$64 single charged particle radiation detector system for external beam cancer radiotherapy. A 1$\times$1 $\mu m^2$ diode measures energy deposition by a single charged particle in the…
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of…
In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time…
In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a…
The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly…
The Large High Altitude Air Shower Observatory is in the R&D phase, in which the Water Cherenkov Detector Array is an important part. The signals of Photo-Multiplier Tubes would vary from single photo electron to 4000 photo electrons, and…
This study investigates the response of Timepix3 semiconductor pixel detectors in proton beams of varying intensities, with a focus on FLASH proton therapy. Using the Timepix3 ASIC chip, we measured the spatial and spectral characteristics…
Thin pad detectors made from 75 $\mu$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that…
Detectors planned for use at the Large Hadron Collider will operate in a radiation field produced by beam collisions. To predict the radiation damage to the components of the detectors, prototype devices are irradiated at test beam…
A strip-readout parallel-plate avalanche counter (SR-PPAC) has been developed aiming at the high detection efficiency and good position resolution in high-intensity heavy-ion measurements. The performance was evaluated using 115 MeV/u…
Purpose: The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultrahigh dose rates. Methods: PSI Gantry 1 treated patients…
The extremely low dark current of silicon carbide (SiC) detectors, even after high-fluence irradiation, was utilized to develop a beam monitoring system for a wide range of particle rates, i.e., from the kHz to the GHz regime. The system is…
CONCERTO is a millimeter-wave imaging instrument that operated on the Atacama Pathfinder Experiment (APEX) telescope from April 2021 to May 2023. Its primary scientific objectives include the study of galaxy clusters through the…