中文
相关论文

相关论文: Timing Properties of Blue-emitting Scintillating F…

200 篇论文

The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…

高能物理 - 实验 · 物理学 2007-05-23 E. C. Aschenauer , J. Baehr , V. Gapienko , B. Hoffmann , A. Kharchilava , H. Luedecke , R. Nahnhauer , R. Shanidze

Wavelength shifting fibers are widely used for light collection from scintillation counters, which allow connection of various scintillation planes to relatively small photocathodes of photodetectors and especially tiny photocathodes of…

仪器与探测器 · 物理学 2022-04-14 I. Alekseev , M. Danilov , V. Rusinov , E. Samigullin , D. Svirida , E. Tarkovsy

A model describing the coincidental timing of scintillating fibers is developed. Fiber geometry, the rate of scintillation decay together with the mean number, spatial dispersion and attenuation of emitted photons is considered. For a…

仪器与探测器 · 物理学 2011-11-04 Petar Žugec

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

仪器与探测器 · 物理学 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

Radiation hardness studies of KURARAY SCSF-78M scintillating fibers and clear fibers from KURARAY and pol.hi.tech. performed under different dose rate conditions in proton and electron beams are summarized. For high dose rates in-situ…

仪器与探测器 · 物理学 2007-05-23 E. C. Aschenauer , J. Baehr , R. Nahnhauer , R. Shanidze , D. Fink , K. H. Maier , M. Muller , H. A. Klose , M. Sprenger

This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…

We measure the decay time and the attenuation length of newly developed wavelength-shifting fibers, YS series from Kuraray, which have fast response. Using a 405 nm laser, the decay times of the YS-2, 4, and 6 are measured to be $3.64 \pm…

仪器与探测器 · 物理学 2024-04-09 Shoma Kodama , Hokuto Kobayashi , Wataru Okinaga , Kota Nakagiri , Yasuhiro Nakajima , Masashi Yokoyama

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

A fibre detector with multianode PM readout for high rate applications was developed for the HERA-B spectometer to cover the area near the beampipe. Such a detector has to operate at particle rates up to 2*10**4 mm**(-2) s**(-1) and has to…

高能物理 - 实验 · 物理学 2007-05-23 H. B. Dreis , F. Eisele , M. Hildebrandt , B. Schmidt , A. Sponsel , M. Ziegler

Most of the time-of-flight systems as well as the fast interaction trigger detectors have large surfaces and the principal requirements for the above mentioned detectors is a good time resolution of the order 100-200ps. The easiest solution…

仪器与探测器 · 物理学 2024-01-18 Varlen Grabski

We present a prototype for the first tracking detector consisting of 250 micron thin scintillating fibers and silicon photomultiplier (SiPM) arrays. The detector has a modular design, each module consists of a mechanical support structure…

We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…

Detectors based on polystyrene scintillator strips with WLS fiber readout are widely used to register charged particles in many high-energy physics experiments. The fibers are placed into grooves or holes along the strip. The detection…

The performance of the $200\times2.5\times1$ cm$^3$ plastic scintillator strip with wavelength shifting fiber read-out by two novel photodetectors called Silicon PhotoMultipliers (SiPMs) is discussed. The advantages of SiPM relative to the…

仪器与探测器 · 物理学 2009-11-11 V. Balagura , M. Danilov , B. Dolgoshein , S. Klemin , R. Mizuk , P. Pakhlov , E. Popova , V. Rusinov , E. Tarkovsky , I. Tikhomirov

We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at…

仪器与探测器 · 物理学 2018-02-14 HCAL collaboration

Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the…

仪器与探测器 · 物理学 2023-02-10 Andrew Wilhelm , Garrett Wendel , Brandon Collins , Doug Cowen , Igor Jovanovic

The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test…

One contribution to the time resolution of a scintillation detector is the signal time spread due to path length variations of the detected photons from a point source. In an experimental study a rectangular scintillator was excited by…

We present and discuss the development and performance of a compact scintillating fiber (SciFi) detector for timing to be used in the Mu3e experiment at very high particle rates. The SciFi detector is read out with multichannel silicon…

仪器与探测器 · 物理学 2022-08-23 A. Bravar , A. Buonaura , S. Corrodi , A. Damyanova , Y. Demets , L. Gerritzen , Ch. Grab , C. Martin Perez , A. Papa

A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…

仪器与探测器 · 物理学 2018-06-27 B. D. Leverington , M. Dziewiecki , L. Renner , R. Runze
‹ 上一页 1 2 3 10 下一页 ›