中文
相关论文

相关论文: Correlation between X-ray tube current exposure ti…

200 篇论文

Pencil x-ray beam imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries due to the illumination of a line instead of an area or volume. However, the pencil beam geometry suffers…

医学物理 · 物理学 2021-02-01 Ignacio O. Romero , Changqing Li

Due to the low X-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device (EMCCD) camera setup, the collimator based narrow beam X-ray luminescence computed tomography (XLCT)…

医学物理 · 物理学 2018-03-14 Wei Zhang , Michael C Lun , Alex Anh-Tu Nguyen , Changqing Li

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT 4…

The use of x-ray imaging in medicine and other research is well known. Generally, the image quality is proportional to the total flux, but high photon energy could severely damage the specimen, so how to decrease the radiation dose while…

医学物理 · 物理学 2017-09-05 Ai-Xin Zhang , Yu-Hang He , Ling-An Wu , Li-Ming Chen , Bing-Bing Wang

Monte Carlo simulation plays an important role in the study of time of flight (TOF) positron emission tomography (PET) prototype. As it can incorporate accurate physical modeling of scintillation detection process, from scintillation light…

Computed Tomography (CT) imaging is one of the most influential diagnostic methods. In clinical reconstruction, an effective energy is used instead of total X-ray spectrum. This approximation causes an accuracy decline. To increase the…

Computed Tomography (CT) imaging, while essential for diagnostics, exposes patients to ionizing radiation. To accurately quantify radiation dosage, this study introduces MIDSX, a specialized open-source Monte Carlo (MC) photon transport…

医学物理 · 物理学 2023-11-29 John Meneghini

X-ray imaging can be efficiently used for high-throughput in-line inspection of industrial products. However, designing a system that satisfies industrial requirements and achieves high accuracy is a challenging problem. The effect of many…

图像与视频处理 · 电气工程与系统科学 2024-01-31 Vladyslav Andriiashen , Robert van Liere , Tristan van Leeuwen , K. Joost Batenburg

X-ray CT dose measurement has mainly been performed using an ionization chamber dosimeter. Therefore, the dose distribution has not been sufficiently studied. We investigated the importance of evaluating the two or three-dimensional dose…

X-ray imaging is a prevalent technique for non-invasively visualizing the interior of the human body and opaque instruments. In most commercial x-ray modalities, an image is formed by measuring the x-rays that pass through the object of…

医学物理 · 物理学 2023-05-23 A. Ben Yehuda , O. Sefi , Y. Klein , R. H Shukrun , H. Schwartz , E. Cohen , S. Shwartz

X-ray variability provides a powerful probe of the innermost regions of active galactic nuclei (AGNs), offering valuable insights into the accretion process and the structure of the corona. Previous studies have established a correlation…

To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital…

Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…

This proceeding discusses the impact of XUV/X-ray irradiation on materials, and how their response is affected by temperature, size, and structure. When materials are exposed to intense XUV/X-ray irradiation, they undergo a series of…

材料科学 · 物理学 2023-11-10 Nikita Medvedev

X-ray is a ubiquitous imaging modality in clinical diagnostics and industrial inspections, thanks to its high penetration power. Conventional x-ray imaging system, equipped with energy-integrating detectors, collects approximately 1000 to…

医学物理 · 物理学 2020-08-24 Zheyuan Zhu , Shuo Pang

We describe a method aiming at increasing the dynamic range of X-ray detectors. Two X-ray exposures of an object are acquired at different dose levels and constitute the only input data. The values of the parameters which are needed to…

医学物理 · 物理学 2007-05-23 Evangelos Matsinos , Wolfgang Kaissl

Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center…

Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with…

Motion management is a critical component of image guidance radiotherapy for lung cancer. We previously proposed a scheme using kV scattered x-ray photons for marker-less real-time image guidance in lung cancer radiotherapy. This study…

医学物理 · 物理学 2020-09-11 Yanqi Huang , Kai Yang , Youfang Lai , Huan Liu , Chenyang Shen , Yuncheng Zhong , Yiping Shao , Xinhua Li , Bob Liu , Xun Jia

Cone beam computed tomography (CBCT) for breast imaging has potential to replace conventional mammograms. However, concerns over dose and image quality prevent CBBCT systems from the clinical trial phase to next stage. The time of flight…

医学物理 · 物理学 2021-02-01 Ignacio O. Romero , Changqing Li
‹ 上一页 1 2 3 10 下一页 ›