中文
相关论文

相关论文: A Deep Learning Approach to Predict Blood Pressure…

200 篇论文

Peripheral Arterial Disease (PAD) is a common form of arterial occlusive disease that is challenging to evaluate at the point-of-care. Hand-held dopplers are the most ubiquitous device used to evaluate circulation and allows providers to…

声音 · 计算机科学 2021-06-17 Adrit Rao , Kevin Battenfield , Oliver Aalami

Background: Sleep staging is a fundamental component in the diagnosis of sleep disorders and the management of sleep health. Traditionally, this analysis is conducted in clinical settings and involves a time-consuming scoring procedure.…

We present a novel learning-based method that achieves state-of-the-art performance on several heart rate estimation benchmarks extracted from photoplethysmography signals (PPG). We consider the evolution of the heart rate in the context of…

机器学习 · 计算机科学 2023-06-16 Valentin Bieri , Paul Streli , Berken Utku Demirel , Christian Holz

Cardiovascular disease has become one of the most significant threats endangering human life and health. Recently, Electrocardiogram (ECG) monitoring has been transformed into remote cardiac monitoring by Holter surveillance. However, the…

信号处理 · 电气工程与系统科学 2022-01-26 Peng Wang , Zihuai Lin , Xucun Yan , Zijiao Chen , Ming Ding , Yang Song , Lu Meng

Purpose:Current methods for diagnosis of PD rely on clinical examination. The accuracy of diagnosis ranges between 73% and 84%, and is influenced by the experience of the clinical assessor. Hence, an automatic, effective and interpretable…

计算机视觉与模式识别 · 计算机科学 2023-12-22 Haozheng Zhang , Edmond S. L. Ho , Xiatian Zhang , Silvia Del Din , Hubert P. H. Shum

Accurate peak detection across diverse cardiac physiological signals, including the Electrocardiogram (ECG), Photoplethysmogram (PPG), Ballistocardiogram (BCG), and Bodyseismography (BSG), is fundamental for cardiovascular monitoring but is…

Epilepsy is the second most common brain disorder after migraine. Automatic detection of epileptic seizures can considerably improve the patients' quality of life. Current Electroencephalogram (EEG)-based seizure detection systems encounter…

信号处理 · 电气工程与系统科学 2018-03-28 Ramy Hussein , Hamid Palangi , Rabab Ward , Z. Jane Wang

Photoplethysmography (PPG) devices are widely used for monitoring cardiovascular function. However, these devices require skin contact, which restrict their use to at-rest short-term monitoring using single-point measurements.…

Remote photoplethysmography (rPPG) allows for noncontact monitoring of blood volume changes from a camera by detecting minor fluctuations in reflected light. Prior applications of rPPG focused on face videos. In this paper we explored the…

计算机视觉与模式识别 · 计算机科学 2023-03-23 Lu Niu , Jeremy Speth , Nathan Vance , Benjamin Sporrer , Adam Czajka , Patrick Flynn

Epilepsy is a neurological disorder and for its detection, encephalography (EEG) is a commonly used clinical approach. Manual inspection of EEG brain signals is a time-consuming and laborious process, which puts heavy burden on neurologists…

计算机视觉与模式识别 · 计算机科学 2018-01-17 Ihsan Ullah , Muhammad Hussain , Emad-ul-Haq Qazi , Hatim Aboalsamh

Pulmonary Arterial Wedge Pressure (PAWP) is an essential cardiovascular hemodynamics marker to detect heart failure. In clinical practice, Right Heart Catheterization is considered a gold standard for assessing cardiac hemodynamics while…

计算机视觉与模式识别 · 计算机科学 2024-04-09 Prasun C Tripathi , Sina Tabakhi , Mohammod N I Suvon , Lawrence Schöb , Samer Alabed , Andrew J Swift , Shuo Zhou , Haiping Lu

Recent studies demonstrated that the average heart rate (HR) can be measured from facial videos based on non-contact remote photoplethysmography (rPPG). However for many medical applications (e.g., atrial fibrillation (AF) detection)…

计算机视觉与模式识别 · 计算机科学 2019-08-01 Zitong Yu , Xiaobai Li , Guoying Zhao

Recent studies showed that Photoplethysmography (PPG) sensors embedded in wearable devices can estimate heart rate (HR) with high accuracy. However, despite of prior research efforts, applying PPG sensor based HR estimation to embedded…

机器学习 · 计算机科学 2023-03-27 Yuntong Zhang , Jingye Xu , Mimi Xie , Wei Wang , Keying Ye , Jing Wang , Dakai Zhu

Parkinson's Disease PD is a progressive neurodegenerative disorder that affects motor and cognitive functions with early diagnosis being critical for effective clinical intervention Electroencephalography EEG offers a noninvasive and…

With the increasing use of smartphones in our daily lives, these devices have become capable of performing many complex tasks. Concerning the need for continuous monitoring of vital signs, especially for the elderly or those with certain…

信号处理 · 电气工程与系统科学 2024-03-29 Taha Samavati , Mahdi Farvardin , Aboozar Ghaffari

The use of photoplethysmogram signal (PPG) for heart and sleep monitoring is commonly found nowadays in smartphones and wrist wearables. Besides common usages, it has been proposed and reported that person information can be extracted from…

音频与语音处理 · 电气工程与系统科学 2019-11-13 Guillermo Cámbara , Jordi Luque , Mireia Farrús

Atrial fibrillation (AF) is a common cardiac arrhythmia with serious health consequences if not detected and treated early. Detecting AF using wearable devices with photoplethysmography (PPG) sensors and deep neural networks has…

信号处理 · 电气工程与系统科学 2023-11-14 Cheng Ding , Zhicheng Guo , Cynthia Rudin , Ran Xiao , Amit Shah , Duc H. Do , Randall J Lee , Gari Clifford , Fadi B Nahab , Xiao Hu

Monitoring blood pressure with non-invasive sensors has gained popularity for providing comfortable user experiences, one of which is a significant function of smart wearables. Although providing a comfortable user experience, such methods…

机器学习 · 计算机科学 2024-12-04 Rui Wang , Mengshi Qi , Yingxia Shao , Anfu Zhou , Huadong Ma

Vital sign measurement using cameras presents opportunities for comfortable, ubiquitous health monitoring. Remote photoplethysmography (rPPG), a foundational technology, enables cardiac measurement through minute changes in light reflected…

计算机视觉与模式识别 · 计算机科学 2025-12-09 Kegang Wang , Jiankai Tang , Yuntao Wang , Xin Liu , Yuxuan Fan , Jiatong Ji , Yuanchun Shi , Daniel McDuff

Remote photoplethysmography (rPPG) is a non-contact technique for measuring cardiac signals from facial videos. High-quality rPPG pulse signals are urgently demanded in many fields, such as health monitoring and emotion recognition.…

图像与视频处理 · 电气工程与系统科学 2020-06-05 Rencheng Song , Huan Chen , Juan Cheng , Chang Li , Yu Liu , Xun Chen