相关论文: Characterization of stilbene-d12 for neutron spect…
We characterized the light output response of a new 140 cm3 stilbene-d12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to…
For radiography applications using fast neutrons simultaneously with gammas we have developed a detector with 16 stilbene crystals in a 4$\times$4 2D array with a 5~mm pitch and a depth of 25~mm. The crystal array is read out by Silicon…
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…
Various neutron diagnostic tools are used in fusion reactors to evaluate different aspects of plasma performance, such as fusion power, power density, ion temperature, fast ion energy, and their spatial distributions. The stilbene…
The scintillation light output response of stilbene crystals has been measured for protons recoiling along the \textit{a}, \textit{b}, and \textit{c'} crystalline axes with energies between 1.3 and 10 MeV using neutrons produced with the…
A time-of-flight spectrometer of neutrons in the energy range (0.05 -- 2.5)$\mu$eV is described. This spectrometer has been tested my measuring the total and differential neutron cross sections for a number of materials: Al, Cu, $^{6}$LiF,…
The integral experiments covering the neutron leakage from geometrically simple assemblies with a 252Cf source inside are very valuable tools usable in validation of transport cross section data, since geometric uncertainties play a much…
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on…
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are…
The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape…
The 15N(p,n) reaction is a promising candidate for the production of monoenergetic neutrons with energies of up to 5.7 MeV at the facilities where the T(p,n)3He reaction cannot be used. The characteristic properties of this reaction were…
The miniBELEN detector is a moderated neutron counter based on the use of $^3$He tubes and high-density polyethylene as moderator. The detector has been designed to have a neutron detection efficiency that is nearly independent from the…
In the present article we describe the calibration measurements of the compact neutron spectrometer at certified PTB neutron source. The spectrometer is based on two diamond detectors enclosing the Li-6 neutron converter. The incident…
A new double time-of-flight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from…
A neutron spectrometer, the European Low-Energy Neutron Spectrometer (ELENS), has been constructed to study exotic nuclei in inverse-kinematics experiments. The spectrometer, which consists of plastic scintillator bars, can be operated in…
Aluminum is a crucial material in the nuclear industry, valued for its ability to perform reliably over time. The manuscript focuses on validating aluminum neutron transport libraries. The validation was conducted by activating samples in…
The production and analysis of distributed sources of 24Na and 222Rn in the Sudbury Neutrino Observatory (SNO) are described. These unique sources provided accurate calibrations of the response to neutrons, produced through…
We report on the neutron response of the LAMBDA spectrometer developed earlier for high-energy gamma-ray measurement. The energy dependent neutron detection efficiency of the spectrometer has been measured using the time-of-flight (TOF)…
A neutron detector based on EJ301 liquid scintillator has been employed at EAST to measure the neutron energy spectrum for D-D fusion plasma. The detector was carefully characterized in different quasi-monoenergetic neutron fields generated…
The ultracold neutron (UCN) source at the Paul Scherrer Institute (PSI) provides high intensities of storable neutrons for fundamental physics experiments. The neutron velocity spectrum parallel to the beamline axis was determined by…