相关论文: Experimental validation of Fastcat kV and MV cone …

200 篇论文

Virtual Imaging Trials (VIT) offer a cost-effective and scalable approach for evaluating medical imaging technologies. Computational phantoms, which mimic real patient anatomy and physiology, play a central role in VITs. However, the…

Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better…

Objective: Dynamic cone-beam CT (CBCT) imaging is highly desired in image-guided radiation therapy to provide volumetric images with high spatial and temporal resolutions to enable applications including tumor motion tracking/prediction and…

医学物理 · 物理学 2023-02-22 You Zhang , Tielige Mengke

Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy (IGRT) to provide updated patient anatomy information for cancer treatments. However, CBCT images often suffer from streaking artifacts and…

计算机视觉与模式识别 · 计算机科学 2023-11-02 Jiarui Zhu , Werxing Chen , Hongfei Sun , Shaohua Zhi , Jing Qin , Jing Cai , Ge Ren

In this manuscript, we investigated the accuracy of the entire chain of phase space files generated by the TrueBeam VirtuaLinac system in clinical treatment plans. Good agreement was obtained between the MC simulation and the clinical…

医学物理 · 物理学 2015-09-24 Yue Yan , Poonam Yadav , Daniel Saenz , Bhudatt R. Paliwal

X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images…

医学物理 · 物理学 2015-05-19 Xun Jia , Bin Dong , Yifei Lou , Steve B. Jiang

Purpose: Developing and testing a framework that integrates real-time catheter shape reconstruction, interactive simulations, and mixed reality visualization to enable accurate monitoring of catheter-vessel interactions during endovascular…

Purpose: CBCT-based adaptive radiotherapy requires daily images for accurate dose calculations. This study investigates the feasibility of applying a single convolutional network to facilitate CBCT-to-CT synthesis for head-and-neck, lung,…

This paper presents pre-launch testing and calibration results for the SVOM/VT (Space-based Variable Objects Monitor, Visible Telescope) Flight Model (FM), validating its performance under simulated space conditions through thermal vacuum…

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

信号处理 · 电气工程与系统科学 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Introduction: This study uses KV CBCT based Synthetic CT (sCT) generated through Velocity workstation and compare the target and normal tissue doses with Adaptive plan CT doses. Methods: Thirty head and neck cancer patients undergoing…

The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was…

Cone-Beam Computed Tomography (CBCT) is widely used for real-time intraoperative imaging due to its low radiation dose and high acquisition speed. However, despite its high resolution, CBCT suffers from significant artifacts and thereby…

图像与视频处理 · 电气工程与系统科学 2025-06-11 Maximilian Tschuchnig , Lukas Lamminger , Philipp Steininger , Michael Gadermayr

We have recently developed a phantom that simulates acute ischemic stroke. We attempted to visualize acute-stage cerebral infarction by applying virtual monochromatic images to this phantom using dual-energy CT (DECT). Virtual monochromatic…

Simulation of x-ray projection images plays an important role in cone beam CT (CBCT) related research projects. A projection image contains primary signal, scatter signal, and noise. It is computationally demanding to perform accurate and…

医学物理 · 物理学 2015-06-04 Xun Jia , Hao Yan , Laura Cervino , Michael Folkerts , Steve B. Jiang

We report on an hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA…

Cone-beam computed tomography (CBCT) using only a few X-ray projection views enables faster scans with lower radiation dose, but the resulting severe under-sampling causes strong artifacts and poor spatial coverage. We address these…

图像与视频处理 · 电气工程与系统科学 2025-06-25 Minmin Yang , Huantao Ren , Senem Velipasalar

The generation of synthetic CT (sCT) images from cone-beam CT (CBCT) data using deep learning methodologies represents a significant advancement in radiation oncology. This systematic review, following PRISMA guidelines and using the PICO…

图像与视频处理 · 电气工程与系统科学 2025-01-27 Alzahra Altalib , Scott McGregor , Chunhui Li , Alessandro Perelli

Daily or weekly cone-beam computed tomography (CBCT) is employed in image-guided radiotherapy (IGRT) for precise patient alignment. However, its clinical utility in quantitative tasks is hindered by severe artifacts and inaccurate Hounsfeld…

医学物理 · 物理学 2026-03-09 Junbo Peng , Huiqiao Xie , Tonghe Wang , Xiangyang Tang , Xiaofeng Yang

Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental…